de Waard–Milliams CO₂ Corrosion Rate Calculator
Estimate a water-wet carbon steel rate from CO₂ partial pressure and fugacity, then apply an independently justified mitigation credit.
Inputs
SI unitsUse absolute pressure and the gas-phase mole fraction. Enter a single measured or assumed net mitigation efficiency.
- Mitigated rate
- 2.12 mm/yr
- Baseline rate
- 8.478 mm/yr
- CO₂ partial
- 1.8 bar(a)
- CO₂ fugacity
- 1.622 bar(a)
Gas, wet steel and mitigation boundary
SchematicScreening for water-wet carbon steel. Confirm water chemistry, phase wetting, corrosion data and sustained mitigation performance.
Calculation details
- Absolute temperature
- 341.15 K
- Partial pressure
- 1.8 bar(a)
- Fugacity coefficient
- 0.90122
- Corrected CO₂ fugacity
- 1.6222 bar(a)
- Remaining modeled rate fraction
- 25 %
- Modeled rate reduction
- 6.359 mm/yr
- Mitigated metric rate
- 2.11959 mm/yr
- Mitigated US rate
- 83.448 mpy
Inputs used
- Operating temperature
- 68 °C
- Total absolute pressure
- 45 bar(a)
- CO₂ in gas phase
- 4 %
- Rate target
- 0.25 mm/yr
- Source of efficiency credit
- Corrosion inhibitor
- Overall efficiency η
- 75 %
Method and limits
Find CO₂ partial pressure
Multiply absolute pressure in bar by the gas-phase CO₂ mole fraction. Convert temperature to kelvin before evaluating either equation.
Correct for fugacity
log₁₀(a) = (0.0031 − 1.4/T_K) × P_bar. The fugacity f is a × P_CO₂. The uninhibited rate is 10^[5.8 − 1710/T_K + 0.67 log₁₀(f)] in mm/yr. Zero CO₂ gives a zero term directly.
Apply the chosen net credit
Multiply by (1 − η), where η is the credited efficiency fraction for a pH effect, protective scale, inhibitor or their measured combined effect. Convert mm/yr to mpy by dividing by 0.0254.