Aluminum 5083 ballast coupon
A ballast compartment trial recorded 69 mg cleaned mass loss from 64 cm² over 504 hours.
Inputs
SI unitsUse cleaned mass loss, total exposed area and the actual exposure duration. Equivalent weights in the presets are illustrative.
- Penetration
- 0.07 mm/yr
- Areal loss
- 0.51 g/(m²·day)
- Current equiv.
- 6.3 µA/cm²
- US rate
- 2.77 mpy
Coupon exposure cell
SchematicCompare with the project limit and inspect for pits. Localized attack can exceed the coupon average.
Calculation details
- Metric penetration
- 0.0704 mm/yr
- US penetration
- 2.7744 mpy
- Areal mass-loss rate
- 0.51 g/(m²·day)
- Equivalent corrosion current
- 6.3 µA/cm²
- mm/yr per µA/cm²
- 0.011187
Inputs used
- Calculation mode
- Coupon mass loss
- Alloy preset
- Aluminum 5083
- Cleaned mass loss
- 69 mg
- Exposed area
- 64 cm²
- Exposure duration
- 504 hr
- Alloy density
- 2.66 g/cm³
- Equivalent weight
- 9.1 g/equiv
Worked calculation
Starting values · SI- 0.069 g ÷ (64 cm² × 504 hr) gives 2.14e-6 g/(cm²·hr).
- Multiply the mass flux by 87,600 ÷ 2.66 to get 0.07045 mm/yr. The G1 mpy constant gives 2.77444 mpy.
- The equivalent current density is 6.29729 µA/cm².
Lower density means the same lost mass implies greater penetration than for steel. Check for attack near dissimilar fasteners.
Method and limits
Normalize the exposure
Use mass loss W in grams, total exposed area A in cm², duration T in hours and density ρ in g/cm³. Include both faces and edges if these were exposed.
Calculate penetration and areal loss
Average penetration = K × W ÷ (A × T × ρ). K is 87,600 for mm/yr and 3,450,000 for mpy. Areal mass loss = 240,000 × W ÷ (A × T) in g/(m²·day). The two published K values are independently rounded.
Convert using equivalent weight
The Faraday relation is mm/yr = 0.00327 × i × EW/ρ, where i is in µA/cm². Divide by the coefficient to convert back. In either Faraday mode, mpy = mm/yr ÷ 0.0254.