CorrosionRateLab
Menu

Duplex 2205 extended exposure

A 2205 coupon lost 18 mg during 2,160 hours of service with 45 cm² exposed.

Inputs

SI units

Use cleaned mass loss, total exposed area and the actual exposure duration. Equivalent weights in the presets are illustrative.

mg
cm²
hr
g/cm³
g/equiv
Penetration
2.08e-3 mm/yr
Areal loss
0.04 g/(m²·day)
Current equiv.
0.2 µA/cm²
US rate
0.08 mpy

Coupon exposure cell

Schematic
Coupon exposure cell (schematic, not to scale)Exposure bathNet metal lossExposed coupon facesMASS LOSS18 mgEXPOSURE2,160 hrAREAL LOSS0.04 g/(m²·day)
Average penetration

Compare with the project limit and inspect for pits. Localized attack can exceed the coupon average.

Reference scale · 0 to 1 mm/yr

Calculation details

Metric penetration
0.0021 mm/yr
US penetration
0.0819 mpy
Areal mass-loss rate
0.04 g/(m²·day)
Equivalent corrosion current
0.2 µA/cm²
mm/yr per µA/cm²
0.010481

Worked calculation

Starting values · SI
  1. 0.018 g ÷ (45 cm² × 2,160 hr) gives 1.85e-7 g/(cm²·hr).
  2. Multiply the mass flux by 87,600 ÷ 7.8 to get 0.00208 mm/yr. The G1 mpy constant gives 0.08191 mpy.
  3. The equivalent current density is 0.19844 µA/cm².

Compare a small cleaned loss with the balance and cleaning blank uncertainty. A short retest may fall below reporting resolution.

Method and limits

  1. Normalize the exposure

    Use mass loss W in grams, total exposed area A in cm², duration T in hours and density ρ in g/cm³. Include both faces and edges if these were exposed.

  2. Calculate penetration and areal loss

    Average penetration = K × W ÷ (A × T × ρ). K is 87,600 for mm/yr and 3,450,000 for mpy. Areal mass loss = 240,000 × W ÷ (A × T) in g/(m²·day). The two published K values are independently rounded.

  3. Convert using equivalent weight

    The Faraday relation is mm/yr = 0.00327 × i × EW/ρ, where i is in µA/cm². Divide by the coefficient to convert back. In either Faraday mode, mpy = mm/yr ÷ 0.0254.