Horizontal coke-breeze trenches
Eight parallel trenches have 5 m effective anode length, 0.22 m coke width and a 1.3 m centerline depth.
Inputs
SI unitsUse surrounding soil resistivity. For low-resistance coke backfill, the optional effective diameter is the column outside diameter.
- Groundbed
- 0.558 Ω
- Single anode
- 2.882 Ω
- Crowding
- 1.55 ×
- Bed drop
- 10.05 V
Anode field and interaction
SchematicVerify field resistivity, backfill contact and actual current distribution before sizing a rectifier.
Calculation details
- Effective anode diameter
- 0.22 m
- Ideal parallel resistance
- 0.3602 Ω
- Mutual resistance term
- 0.1979 Ω
- Total modeled resistance
- 0.5581 Ω
- Target minus modeled resistance
- 0.4419 Ω
- Ideal-parallel efficiency
- 64.54 %
Inputs used
- Groundbed layout
- Horizontal parallel trenches
- Soil resistivity
- 21 Ω·m
- Effective length
- 5 m
- Bare anode diameter
- 0.075 m
- Coke column diameter
- 0.22 m
- Anodes in parallel
- 8
- Center spacing
- 7 m
- Trench center depth
- 1.3 m
- Design current
- 18 A
- Resistance target
- 1 Ω
Worked calculation
Starting values · SI- The single electrode has 2.88198 Ω using the horizontal geometry and 0.22 m effective diameter.
- Ideal parallel resistance is 0.36025 Ω. Adding 0.19789 Ω gives 0.55814 Ω.
- At 18 A, groundbed voltage drop is 10.0465 V.
The single-anode calculation uses horizontal burial depth. The horizontal array interference estimate should be verified with the actual layout.
Method and limits
Estimate a single anode
For a shallow vertical electrode, R = ρ[ln(8L/d) − 1]/(2πL). Use the conductive coke column diameter and length when it functions as an equivalent electrode.
Apply trench depth if horizontal
With centerline depth h, set s = 2h and q = √(s² + L²). Dwight’s horizontal bracket is ln[4L(L + q)/(d × s)] + (s − q)/L − 1. Multiply by ρ/(2πL).
Estimate row interaction
With N > 1, add ρ × ln(0.656N)/(πNS) to R_single/N for center spacing S. This Sunde term is for a vertical row. Applying it to parallel horizontal trenches is an approximation. The voltage drop is design current × modeled bed resistance.