CorrosionRateLab
Menu

Horizontal coke-breeze trenches

Eight parallel trenches have 5 m effective anode length, 0.22 m coke width and a 1.3 m centerline depth.

Inputs

SI units

Use surrounding soil resistivity. For low-resistance coke backfill, the optional effective diameter is the column outside diameter.

Ω·m
m
m
m
m
m
A
Ω
Groundbed
0.558 Ω
Single anode
2.882 Ω
Crowding
1.55 ×
Bed drop
10.05 V

Anode field and interaction

Schematic
Anode field and interaction (schematic, not to scale)Trench end section4 of 8 anodesEFFECTIVE Ø0.22 mBURIAL DEPTH1.3 mROW RESISTANCE0.558 Ω
Within resistance target

Verify field resistivity, backfill contact and actual current distribution before sizing a rectifier.

Modeled resistance ÷ selected target

Calculation details

Effective anode diameter
0.22 m
Ideal parallel resistance
0.3602 Ω
Mutual resistance term
0.1979 Ω
Total modeled resistance
0.5581 Ω
Target minus modeled resistance
0.4419 Ω
Ideal-parallel efficiency
64.54 %

Worked calculation

Starting values · SI
  1. The single electrode has 2.88198 Ω using the horizontal geometry and 0.22 m effective diameter.
  2. Ideal parallel resistance is 0.36025 Ω. Adding 0.19789 Ω gives 0.55814 Ω.
  3. At 18 A, groundbed voltage drop is 10.0465 V.

The single-anode calculation uses horizontal burial depth. The horizontal array interference estimate should be verified with the actual layout.

Method and limits

  1. Estimate a single anode

    For a shallow vertical electrode, R = ρ[ln(8L/d) − 1]/(2πL). Use the conductive coke column diameter and length when it functions as an equivalent electrode.

  2. Apply trench depth if horizontal

    With centerline depth h, set s = 2h and q = √(s² + L²). Dwight’s horizontal bracket is ln[4L(L + q)/(d × s)] + (s − q)/L − 1. Multiply by ρ/(2πL).

  3. Estimate row interaction

    With N > 1, add ρ × ln(0.656N)/(πNS) to R_single/N for center spacing S. This Sunde term is for a vertical row. Applying it to parallel horizontal trenches is an approximation. The voltage drop is design current × modeled bed resistance.