CorrosionRateLab
Menu

Repeat readings at the same thickness

Both surveys and the commissioned reading returned 9.6 mm at the same location.

Inputs

SI units

Use comparable readings from the same location. For a short-term-only calculation, leave installed thickness and years in service blank.

mm
mm
mm
mm
yr
yr
Governing rate
0 mm/yr
Wall margin
3.3 mm
Remaining life
—
UT interval
5 yr

UT thickness history

Schematic
UT thickness history (schematic, not to scale)Measured UTRetirement limit20112025YearCURRENT WALL9.6 mmRETIREMENT6.3 mmINSPECTION5 yr
No measurable thinning

No finite life follows from a zero measured rate. The reported interval is the selected cap only. Confirm UT uncertainty.

Usable fraction of current wall

Calculation details

Short-term thinning rate
0 mm/yr
Long-term thinning rate
0 mm/yr
Years between UT readings
5 yr
Governing thinning rate
0 mm/yr
Half-life before cap
—
Screened inspection interval
5 yr

Worked calculation

Starting values · SI
  1. Current wall minus retirement wall is 9.6 − 6.3 = 3.3 mm.
  2. Short-term loss rate is 0 mm/yr and long-term loss rate is 0 mm/yr.
  3. The model shows the 5 yr cap and no finite life.

A zero computed rate gives no finite life. Treat the five-year cap as a screening bound and review UT sensitivity.

Method and limits

  1. Compare short and long histories

    Short-term rate = (previous UT − current UT) ÷ elapsed years. Long-term rate = (installed thickness − current UT) ÷ years in service when both inputs are given. Use the larger credible rate.

  2. Measure the retirement margin

    Allowance = current thickness − retirement thickness. At or below retirement, the screen returns zero life and zero interval. Confirm a rising thickness trend before assigning a rate.

  3. Apply the half-life rule

    Remaining life = allowance ÷ governing rate. The screening interval is the smaller of half the remaining life and the selected cap. A zero measured rate produces a cap-only interval and no finite life estimate.