CorrosionRateLab
Menu

Wall below retirement thickness

The smallest repeatable reading is 5.8 mm against a 6.3 mm retirement thickness.

Inputs

SI units

Use comparable readings from the same location. For a short-term-only calculation, leave installed thickness and years in service blank.

mm
mm
mm
mm
yr
yr
Governing rate
0.76 mm/yr
Wall margin
-0.5 mm
Remaining life
0 yr
UT interval
0 yr

UT thickness history

Schematic
UT thickness history (schematic, not to scale)Measured UTRetirement limit20112025YearCURRENT WALL5.8 mmRETIREMENT6.3 mmINSPECTION0 yr
Immediate disposition required

At or below retirement thickness. Escalate for repair, replacement or qualified disposition before continued operation.

Retirement limit reached

Calculation details

Short-term thinning rate
0.76 mm/yr
Long-term thinning rate
0.42 mm/yr
Years between UT readings
5 yr
Governing thinning rate
0.76 mm/yr
Half-life before cap
0 yr
Screened inspection interval
0 yr

Worked calculation

Starting values · SI
  1. Current wall minus retirement wall is 5.8 − 6.3 = -0.5 mm.
  2. Short-term loss rate is 0.76 mm/yr and long-term loss rate is 0.42143 mm/yr.
  3. Retirement is reached, so reported life and interval are both zero.

Review the negative wall margin with the integrity team. Confirm the reading and take action under the governing inspection plan.

Method and limits

  1. Compare short and long histories

    Short-term rate = (previous UT − current UT) ÷ elapsed years. Long-term rate = (installed thickness − current UT) ÷ years in service when both inputs are given. Use the larger credible rate.

  2. Measure the retirement margin

    Allowance = current thickness − retirement thickness. At or below retirement, the screen returns zero life and zero interval. Confirm a rising thickness trend before assigning a rate.

  3. Apply the half-life rule

    Remaining life = allowance ÷ governing rate. The screening interval is the smaller of half the remaining life and the selected cap. A zero measured rate produces a cap-only interval and no finite life estimate.