CorrosionRateLab
Menu

Short-term UT rate governs

A header declined from 9.6 mm in 2020 to 8.3 mm in 2025. It began at 11.7 mm 14 years earlier. Retirement is 6.3 mm.

Inputs

SI units

Use comparable readings from the same location. For a short-term-only calculation, leave installed thickness and years in service blank.

mm
mm
mm
mm
yr
yr
Governing rate
0.26 mm/yr
Wall margin
2 mm
Remaining life
7.69 yr
UT interval
3.85 yr

UT thickness history

Schematic
UT thickness history (schematic, not to scale)Measured UTRetirement limit20112025YearCURRENT WALL8.3 mmRETIREMENT6.3 mmINSPECTION3.85 yr
Thickness above retirement

Confirm the governing rates, inspection method, service class and current code before setting a due date.

Usable fraction of current wall

Calculation details

Short-term thinning rate
0.26 mm/yr
Long-term thinning rate
0.24 mm/yr
Years between UT readings
5 yr
Governing thinning rate
0.26 mm/yr
Half-life before cap
3.85 yr
Screened inspection interval
3.85 yr

Worked calculation

Starting values · SI
  1. Current wall minus retirement wall is 8.3 − 6.3 = 2 mm.
  2. Short-term loss rate is 0.26 mm/yr and long-term loss rate is 0.24286 mm/yr.
  3. Remaining life is 7.69231 yr. Half-life is 3.84615 yr, giving a screened interval of 3.84615 yr.

Use the higher short-term rate to calculate remaining life and compare half-life with the five-year cap.

Method and limits

  1. Compare short and long histories

    Short-term rate = (previous UT − current UT) ÷ elapsed years. Long-term rate = (installed thickness − current UT) ÷ years in service when both inputs are given. Use the larger credible rate.

  2. Measure the retirement margin

    Allowance = current thickness − retirement thickness. At or below retirement, the screen returns zero life and zero interval. Confirm a rising thickness trend before assigning a rate.

  3. Apply the half-life rule

    Remaining life = allowance ÷ governing rate. The screening interval is the smaller of half the remaining life and the selected cap. A zero measured rate produces a cap-only interval and no finite life estimate.