Short-term UT rate governs
A header declined from 9.6 mm in 2020 to 8.3 mm in 2025. It began at 11.7 mm 14 years earlier. Retirement is 6.3 mm.
Inputs
SI unitsUse comparable readings from the same location. For a short-term-only calculation, leave installed thickness and years in service blank.
- Governing rate
- 0.26 mm/yr
- Wall margin
- 2 mm
- Remaining life
- 7.69 yr
- UT interval
- 3.85 yr
UT thickness history
SchematicConfirm the governing rates, inspection method, service class and current code before setting a due date.
Calculation details
- Short-term thinning rate
- 0.26 mm/yr
- Long-term thinning rate
- 0.24 mm/yr
- Years between UT readings
- 5 yr
- Governing thinning rate
- 0.26 mm/yr
- Half-life before cap
- 3.85 yr
- Screened inspection interval
- 3.85 yr
Inputs used
- Previous UT thickness
- 9.6 mm
- Previous year
- 2,020
- Current UT thickness
- 8.3 mm
- Current year
- 2,025
- Retirement thickness
- 6.3 mm
- Installed thickness
- 11.7 mm
- Years in service
- 14 yr
- Inspection cap preset
- API 570 Class 1 · 5 yr
- Maximum interval
- 5 yr
Worked calculation
Starting values · SI- Current wall minus retirement wall is 8.3 − 6.3 = 2 mm.
- Short-term loss rate is 0.26 mm/yr and long-term loss rate is 0.24286 mm/yr.
- Remaining life is 7.69231 yr. Half-life is 3.84615 yr, giving a screened interval of 3.84615 yr.
Use the higher short-term rate to calculate remaining life and compare half-life with the five-year cap.
Method and limits
Compare short and long histories
Short-term rate = (previous UT − current UT) ÷ elapsed years. Long-term rate = (installed thickness − current UT) ÷ years in service when both inputs are given. Use the larger credible rate.
Measure the retirement margin
Allowance = current thickness − retirement thickness. At or below retirement, the screen returns zero life and zero interval. Confirm a rising thickness trend before assigning a rate.
Apply the half-life rule
Remaining life = allowance ÷ governing rate. The screening interval is the smaller of half the remaining life and the selected cap. A zero measured rate produces a cap-only interval and no finite life estimate.