316L immersion coupon
A 316L plate exposed to a mildly corrosive stream lost 44 mg. The 52 cm² exposed area stayed immersed for 1,440 hours.
Inputs
SI unitsUse cleaned mass loss, total exposed area and the actual exposure duration. Equivalent weights in the presets are illustrative.
- Penetration
- 0.01 mm/yr
- Areal loss
- 0.14 g/(m²·day)
- Current equiv.
- 0.62 µA/cm²
- US rate
- 0.25 mpy
Coupon exposure cell
SchematicCompare with the project limit and inspect for pits. Localized attack can exceed the coupon average.
Calculation details
- Metric penetration
- 0.0065 mm/yr
- US penetration
- 0.254 mpy
- Areal mass-loss rate
- 0.14 g/(m²·day)
- Equivalent corrosion current
- 0.62 µA/cm²
- mm/yr per µA/cm²
- 0.010449
Inputs used
- Calculation mode
- Coupon mass loss
- Alloy preset
- 316L stainless steel
- Cleaned mass loss
- 44 mg
- Exposed area
- 52 cm²
- Exposure duration
- 1,440 hr
- Alloy density
- 7.98 g/cm³
- Equivalent weight
- 25.5 g/equiv
Worked calculation
Starting values · SI- 0.044 g ÷ (52 cm² × 1,440 hr) gives 5.88e-7 g/(cm²·hr).
- Multiply the mass flux by 87,600 ÷ 7.98 to get 0.00645 mm/yr. The G1 mpy constant gives 0.25404 mpy.
- The equivalent current density is 0.61731 µA/cm².
A small average loss does not quantify crevice attack at the fixture. Report how the fixture and masked area were handled.
Method and limits
Normalize the exposure
Use mass loss W in grams, total exposed area A in cm², duration T in hours and density ρ in g/cm³. Include both faces and edges if these were exposed.
Calculate penetration and areal loss
Average penetration = K × W ÷ (A × T × ρ). K is 87,600 for mm/yr and 3,450,000 for mpy. Areal mass loss = 240,000 × W ÷ (A × T) in g/(m²·day). The two published K values are independently rounded.
Convert using equivalent weight
The Faraday relation is mm/yr = 0.00327 × i × EW/ρ, where i is in µA/cm². Divide by the coefficient to convert back. In either Faraday mode, mpy = mm/yr ÷ 0.0254.