316L immersion coupon

A 316L plate exposed to a mildly corrosive stream lost 44 mg. The 52 cm² exposed area stayed immersed for 1,440 hours.

Inputs

SI units

Use cleaned mass loss, total exposed area and the actual exposure duration. Equivalent weights in the presets are illustrative.

mg
cm²
hr
g/cm³
g/equiv
Penetration
0.01 mm/yr
Areal loss
0.14 g/(m²·day)
Current equiv.
0.62 µA/cm²
US rate
0.25 mpy

Coupon exposure cell

Schematic
Coupon exposure cell (schematic, not to scale)Exposure bathNet metal lossExposed coupon facesMASS LOSS44 mgEXPOSURE1,440 hrAREAL LOSS0.14 g/(m²·day)
Average penetration

Compare with the project limit and inspect for pits. Localized attack can exceed the coupon average.

Reference scale · 0 to 1 mm/yr

Calculation details

Metric penetration
0.0065 mm/yr
US penetration
0.254 mpy
Areal mass-loss rate
0.14 g/(m²·day)
Equivalent corrosion current
0.62 µA/cm²
mm/yr per µA/cm²
0.010449

Worked calculation

Starting values · SI
  1. 0.044 g ÷ (52 cm² × 1,440 hr) gives 5.88e-7 g/(cm²·hr).
  2. Multiply the mass flux by 87,600 ÷ 7.98 to get 0.00645 mm/yr. The G1 mpy constant gives 0.25404 mpy.
  3. The equivalent current density is 0.61731 µA/cm².

A small average loss does not quantify crevice attack at the fixture. Report how the fixture and masked area were handled.

Method and limits

  1. Normalize the exposure

    Use mass loss W in grams, total exposed area A in cm², duration T in hours and density ρ in g/cm³. Include both faces and edges if these were exposed.

  2. Calculate penetration and areal loss

    Average penetration = K × W ÷ (A × T × ρ). K is 87,600 for mm/yr and 3,450,000 for mpy. Areal mass loss = 240,000 × W ÷ (A × T) in g/(m²·day). The two published K values are independently rounded.

  3. Convert using equivalent weight

    The Faraday relation is mm/yr = 0.00327 × i × EW/ρ, where i is in µA/cm². Divide by the coefficient to convert back. In either Faraday mode, mpy = mm/yr ÷ 0.0254.