CorrosionRateLab
Menu

Inhibited wet gas carbon steel

Wet gas at 68 °C and 45 bar(a) contains 4 mol% CO₂, with 75% credited inhibitor effectiveness for comparison.

Inputs

SI units

Use absolute pressure and the gas-phase mole fraction. Enter a single measured or assumed net mitigation efficiency.

°C
bar(a)
%
mm/yr
% Enter one independently justified net efficiency.
Mitigated rate
2.12 mm/yr
Baseline rate
8.478 mm/yr
CO₂ partial
1.8 bar(a)
CO₂ fugacity
1.622 bar(a)

Gas, wet steel and mitigation boundary

Schematic
Gas, wet steel and mitigation boundary (schematic, not to scale)CO₂ gasWater-wet carbon steelWet steel boundaryNet credit shown in cyanCO₂ PARTIAL1.8 bar(a)FUGACITY1.622 bar(a)MITIGATED RATE2.12 mm/yr
Above modeled rate target

Screening for water-wet carbon steel. Confirm water chemistry, phase wetting, corrosion data and sustained mitigation performance.

Mitigated rate ÷ selected screening target

Calculation details

Absolute temperature
341.15 K
Partial pressure
1.8 bar(a)
Fugacity coefficient
0.90122
Corrected CO₂ fugacity
1.6222 bar(a)
Remaining modeled rate fraction
25 %
Modeled rate reduction
6.359 mm/yr
Mitigated metric rate
2.11959 mm/yr
Mitigated US rate
83.448 mpy

Worked calculation

Starting values · SI
  1. The gas fraction gives 1.8 bar(a) partial pressure. The fugacity coefficient is 0.90122.
  2. The calculated CO₂ fugacity is 1.62219 bar(a) and the baseline rate is 8.47835 mm/yr.
  3. The 75% net efficiency gives 2.11959 mm/yr, or 83.44829 mpy.

Calculate the partial pressure first, then compare the baseline and mitigated rates. Verify field evidence for the credited efficiency.

Method and limits

  1. Find CO₂ partial pressure

    Multiply absolute pressure in bar by the gas-phase CO₂ mole fraction. Convert temperature to kelvin before evaluating either equation.

  2. Correct for fugacity

    log₁₀(a) = (0.0031 − 1.4/T_K) × P_bar. The fugacity f is a × P_CO₂. The uninhibited rate is 10^[5.8 − 1710/T_K + 0.67 log₁₀(f)] in mm/yr. Zero CO₂ gives a zero term directly.

  3. Apply the chosen net credit

    Multiply by (1 − η), where η is the credited efficiency fraction for a pH effect, protective scale, inhibitor or their measured combined effect. Convert mm/yr to mpy by dividing by 0.0254.