Wet gas with zero entered CO₂
The gas analysis reports zero CO₂ in the test case. Water is still present.
Inputs
SI unitsUse absolute pressure and the gas-phase mole fraction. Enter a single measured or assumed net mitigation efficiency.
- Mitigated rate
- 0 mm/yr
- Baseline rate
- 0 mm/yr
- CO₂ partial
- 0 bar(a)
- CO₂ fugacity
- 0 bar(a)
Gas, wet steel and mitigation boundary
SchematicA zero model term gives a zero output. Verify the assumptions and assess other active corrosion mechanisms.
Calculation details
- Absolute temperature
- 341.15 K
- Partial pressure
- 0 bar(a)
- Fugacity coefficient
- 0.90122
- Corrected CO₂ fugacity
- 0 bar(a)
- Remaining modeled rate fraction
- 100 %
- Modeled rate reduction
- 0 mm/yr
- Mitigated metric rate
- 0 mm/yr
- Mitigated US rate
- 0 mpy
Inputs used
- Operating temperature
- 68 °C
- Total absolute pressure
- 45 bar(a)
- CO₂ in gas phase
- 0 %
- Rate target
- 0.25 mm/yr
- Source of efficiency credit
- Corrosion inhibitor
- Overall efficiency η
- 0 %
Worked calculation
Starting values · SI- The gas fraction gives 0 bar(a) partial pressure. The fugacity coefficient is 0.90122.
- The calculated CO₂ fugacity is 0 bar(a) and the baseline rate is 0 mm/yr.
- The 0% net efficiency gives 0 mm/yr, or 0 mpy.
The CO₂ term vanishes without taking a logarithm of zero. Other mechanisms can still be active.
Method and limits
Find CO₂ partial pressure
Multiply absolute pressure in bar by the gas-phase CO₂ mole fraction. Convert temperature to kelvin before evaluating either equation.
Correct for fugacity
log₁₀(a) = (0.0031 − 1.4/T_K) × P_bar. The fugacity f is a × P_CO₂. The uninhibited rate is 10^[5.8 − 1710/T_K + 0.67 log₁₀(f)] in mm/yr. Zero CO₂ gives a zero term directly.
Apply the chosen net credit
Multiply by (1 − η), where η is the credited efficiency fraction for a pH effect, protective scale, inhibitor or their measured combined effect. Convert mm/yr to mpy by dividing by 0.0254.