CorrosionRateLab
Menu

Weight-Loss Corrosion Rate Calculator

Turn cleaned coupon mass loss into average penetration and convert between corrosion current density, mm/yr and mpy.

Inputs

SI units

Use cleaned mass loss, total exposed area and the actual exposure duration. Equivalent weights in the presets are illustrative.

mg
cm²
hr
g/cm³
g/equiv
Penetration
0.17 mm/yr
Areal loss
3.71 g/(m²·day)
Current equiv.
14.81 µA/cm²
US rate
6.78 mpy

Coupon exposure cell

Schematic
Coupon exposure cell (schematic, not to scale)Exposure bathNet metal lossExposed coupon facesMASS LOSS428 mgEXPOSURE720 hrAREAL LOSS3.71 g/(m²·day)
Average penetration

Compare with the project limit and inspect for pits. Localized attack can exceed the coupon average.

Reference scale · 0 to 1 mm/yr

Calculation details

Metric penetration
0.1721 mm/yr
US penetration
6.7771 mpy
Areal mass-loss rate
3.71 g/(m²·day)
Equivalent corrosion current
14.81 µA/cm²
mm/yr per µA/cm²
0.011616

Method and limits

  1. Normalize the exposure

    Use mass loss W in grams, total exposed area A in cm², duration T in hours and density ρ in g/cm³. Include both faces and edges if these were exposed.

  2. Calculate penetration and areal loss

    Average penetration = K × W ÷ (A × T × ρ). K is 87,600 for mm/yr and 3,450,000 for mpy. Areal mass loss = 240,000 × W ÷ (A × T) in g/(m²·day). The two published K values are independently rounded.

  3. Convert using equivalent weight

    The Faraday relation is mm/yr = 0.00327 × i × EW/ρ, where i is in µA/cm². Divide by the coefficient to convert back. In either Faraday mode, mpy = mm/yr ÷ 0.0254.