ASME B30.9 · Planar statics

Centered CG with stepped tank lugs

Both picks lie 7 ft from the CG in plan. One lug is 3 ft higher than its opposite lug.

Inputs

Load and tolerance
lb
in
Left pickup A
ft
ft
ft
Right pickup B
ft
ft
ft
Back to results ↑

Results

Static screeningEdit inputs ↓
Pickup geometry and center of gravityTENSION A19,269.88lbfTENSION B15,578.93lbfINWARD FORCE12,250lbfHOOK OFFSET0inCG PLUMBABPICKUP SPANd₁d₂Plumb tolerance0%Left lineRight lineCG projectionLift screening only · verify with rigger / PE and OEM chart

Schematic geometry. Margin bars mark 100% of the entered limit.

Screening results

Compare these results with the approved equipment and lift plan.

Left sling tension
19,269.88 lbf
Right sling tension
15,578.93 lbf
Inward force per pickup
12,250 lbf
Measured hook offset, + toward B
0 in
Left angle from horizontal
50.53 °
Right angle from horizontal
38.16 °
Measured hook height above CG
9 ft

Equal horizontal distances do not guarantee equal tensions. The higher lug has less vertical rise to the common hook.

Left sling tension 19,269.88 lbf · Right sling tension 15,578.93 lbf

Locate the hook

H lies on both sling-length circles

Circle centers are the two pickups. Select the upper intersection above both pickups and measure its horizontal offset from the CG.

Resolve the leg forces

R = W / (tan θ₁ + tan θ₂)

At the plumb target, each sling carries the same horizontal component R. The vertical components follow from the individual slopes.

Get each tension

Tᵢ = R / cos θᵢ

Angled tensions are based on the mean of the two target hook elevations within the entered plumb tolerance.

Four vertical pickups

ΣR = W; right pair = Wx/B; far pair = Wy/L

Use a level rectangle and vertical, tension-only lines. Force and moment balance bound each corner reaction. A unique four-leg share needs stiffness, stretch and compatibility or an engineered equalizer.

For two angled legs, use one plane and the declared attitude. The four-pickup bounds apply to vertical reactions on a level rectangle. The individual maxima are separate equilibrium cases. Verify line geometry, load stability, pickup strength and tagged WLL with a qualified rigger.