ASME B30.9 · Planar statics

Offset-CG generator with level pickups

A generator weighs 16,000 lb. The CG projection is 4 ft from the left pickup and 9 ft from the right.

Inputs

Load and tolerance
lb
in
Left pickup A
ft
ft
ft
Right pickup B
ft
ft
ft
Back to results ↑

Results

Static screeningEdit inputs ↓
Pickup geometry and center of gravityTENSION A12,384.38lbfTENSION B7,410.21lbfINWARD FORCE5,538.46lbfHOOK OFFSET0inCG PLUMBABPICKUP SPANd₁d₂Plumb tolerance0%Left lineRight lineCG projectionLift screening only · verify with rigger / PE and OEM chart

Schematic geometry. Margin bars mark 100% of the entered limit.

Screening results

Compare these results with the approved equipment and lift plan.

Left sling tension
12,384.38 lbf
Right sling tension
7,410.21 lbf
Inward force per pickup
5,538.46 lbf
Measured hook offset, + toward B
0 in
Left angle from horizontal
63.43 °
Right angle from horizontal
41.63 °
Measured hook height above CG
9 ft

The shorter horizontal reach produces the steeper leg. Compare the inward pickup force with the two vertical reactions.

Left sling tension 12,384.38 lbf · Right sling tension 7,410.21 lbf

Locate the hook

H lies on both sling-length circles

Circle centers are the two pickups. Select the upper intersection above both pickups and measure its horizontal offset from the CG.

Resolve the leg forces

R = W / (tan θ₁ + tan θ₂)

At the plumb target, each sling carries the same horizontal component R. The vertical components follow from the individual slopes.

Get each tension

Tᵢ = R / cos θᵢ

Angled tensions are based on the mean of the two target hook elevations within the entered plumb tolerance.

Four vertical pickups

ΣR = W; right pair = Wx/B; far pair = Wy/L

Use a level rectangle and vertical, tension-only lines. Force and moment balance bound each corner reaction. A unique four-leg share needs stiffness, stretch and compatibility or an engineered equalizer.

For two angled legs, use one plane and the declared attitude. The four-pickup bounds apply to vertical reactions on a level rectangle. The individual maxima are separate equilibrium cases. Verify line geometry, load stability, pickup strength and tagged WLL with a qualified rigger.