Dynamic pressure
q = ½ρV² ≈ 0.00256 Vmph² psf
The US approximation assumes standard sea-level density. The calculator uses the entered density in both unit systems.
ASME B30.5 · ASCE 7 context
A 10 m/s gust is measured at lift height. The site limit is 8.5 m/s and the entered crane limit is 11 m/s.
Schematic geometry. Margin bars mark 100% of the entered limit.
The lower site value controls this comparison. The wind-limit status follows gust speed independently of the modeled side force.
Effective sail area, Cd × A 18.2 m² · Horizontal wind force 1.06 kN
q = ½ρV² ≈ 0.00256 Vmph² psf
The US approximation assumes standard sea-level density. The calculator uses the entered density in both unit systems.
Fw = q × Cd × A; φ = atan(Fw/W)
Use the largest projected area in the lift orientation. The idealized static offset is line length × sin φ.
Margin = min(OEM limit, site limit) − gust
Use the limits for the actual crane configuration and load sail area.
Estimate steady payload drag only. Use the crane manufacturer’s instructions and load-specific wind limit. This model excludes transient motion, the boom’s own wind loading and ASCE 7 exposure and gust factors.
CraneRiggingLab · Lift screening worksheet
ASME B30.5 · ASCE 7 context · SI · kg
Screening estimates only. Have a qualified rigger and a professional engineer (PE), where required, review the lift plan. Use the OEM chart for the actual configuration.
Estimate steady payload drag only. Use the crane manufacturer’s instructions and load-specific wind limit. This model excludes transient motion, the boom’s own wind loading and ASCE 7 exposure and gust factors.