ASME B30.5 · ASCE 7 context

Wide precast panel in a lift-height gust

A 34,000 lb precast panel presents 560 ft² broadside during a 21 mph gust.

Inputs

Suspended load and profile
lb
ft²
ft
Gust and cutoff
mph
mph
mph
slug/ft³
Back to results ↑

Results

Static screeningEdit inputs ↓
Suspended-load pendulumSAIL AREA1,008ft²SIDE FORCE1,136.43lbfSWAY ANGLE1.91°GUST MARGIN1mphHOOKPLUMBφ 1.91°Side forceGust speed limit95.45%Suspended loadWind forceGravity referenceLift screening only · verify with rigger / PE and OEM chart

Schematic geometry. Margin bars mark 100% of the entered limit.

Screening results
  • Entered gust is within 10% of the lower wind limit.
  • Generic drag coefficient selected. Verify projected orientation and drag factor for the load.
Effective sail area, Cd × A
1,008 ft²
Horizontal wind force
1,136.43 lbf
Equilibrium swing angle
1.91 °
Gust margin to cutoff
1 mph
Dynamic wind pressure
1.13 psf
Static horizontal offset
2.27 ft
Lower OEM or site gust limit
22 mph

Multiply projected area by the assumed drag coefficient. The steady swing angle depends on the side-force-to-weight ratio.

Effective sail area, Cd × A 1,008 ft² · Horizontal wind force 1,136.43 lbf

Dynamic pressure

q = ½ρV² ≈ 0.00256 Vmph² psf

The US approximation assumes standard sea-level density. The calculator uses the entered density in both unit systems.

Sail force and deflection

Fw = q × Cd × A; φ = atan(Fw/W)

Use the largest projected area in the lift orientation. The idealized static offset is line length × sin φ.

Wind headroom

Margin = min(OEM limit, site limit) − gust

Use the limits for the actual crane configuration and load sail area.

Estimate steady payload drag only. Use the crane manufacturer’s instructions and load-specific wind limit. This model excludes transient motion, the boom’s own wind loading and ASCE 7 exposure and gust factors.