Worked example
Estimated tightening torque 72.2 N·m
- The M10 × 1.5 thread has a tensile stress area near 58 mm². Multiply it by the 830 MPa proof stress, then take 75% for the target clamp force.
- Multiply that force by 0.010 m and K = 0.20 for dry threads. For the same force at K = 0.15, the oiled case uses 75% of the dry torque.
Before using this result. Verify the actual coating, lubricant and assembly specification. This comparison uses illustrative nut factors for the same preload.
Formulas and assumptions
- T = KDF
- Use N of clamp force and meters of nominal bolt diameter to get N·m. The worksheet can invert the equation to estimate F from torque.
- Fproof = Sproof Aₜ
- Tensile stress area is π(D − cP)²/4. Use c = 0.938194 for metric and 0.9743 for Unified threads. P is pitch.
- dᵈʳⁱˡˡ = D − (% thread)P / 76.98
- This is a cut tap geometry estimate. Enter a candidate drill to see the achieved percentage of nominal thread height.
Engineering references
Frequently asked questions
Is the M10 oiled comparison a reduction in clamp force?
Both comparison rows hold estimated clamp force constant. The torque changes because the nut factor changes.
Should I use the same torque for an M10 Class 8.8 bolt?
Class 8.8 has a different proof stress. Choose the correct grade and use the assembly specification to set the target load.