Worked example
Estimated tightening torque 150.04 N·m
- Use the fine pitch of 1.25 mm and 970 MPa proof stress for Class 12.9. Multiply the tensile stress area by 970 MPa and take 70% for target preload.
- Multiply the clamp force by 0.012 m and the dry example nut factor. The 10.8 mm check uses the same pitch but its own thread-height calculation.
Before using this result. Verify the certified fastener grade, mating threads and surface finish. Check embrittlement, coating and assembly requirements for high-strength bolts.
Formulas and assumptions
- T = KDF
- Use N of clamp force and meters of nominal bolt diameter to get N·m. The worksheet can invert the equation to estimate F from torque.
- Fproof = Sproof Aₜ
- Tensile stress area is π(D − cP)²/4. Use c = 0.938194 for metric and 0.9743 for Unified threads. P is pitch.
- dᵈʳⁱˡˡ = D − (% thread)P / 76.98
- This is a cut tap geometry estimate. Enter a candidate drill to see the achieved percentage of nominal thread height.
Engineering references
Frequently asked questions
How much does dropping the M12 target from 70% to 60% change torque?
With the same bolt and nut factor, torque scales with target preload. The 60% setting gives about 86% of the torque at 70%.
Is 1.25 mm the ordinary M12 coarse pitch?
Coarse M12 uses 1.75 mm. This example deliberately uses the fine M12 × 1.25 size.