Worked example

Estimated tightening torque 150.04 N·m

  1. Use the fine pitch of 1.25 mm and 970 MPa proof stress for Class 12.9. Multiply the tensile stress area by 970 MPa and take 70% for target preload.
  2. Multiply the clamp force by 0.012 m and the dry example nut factor. The 10.8 mm check uses the same pitch but its own thread-height calculation.

Before using this result. Verify the certified fastener grade, mating threads and surface finish. Check embrittlement, coating and assembly requirements for high-strength bolts.

Formulas and assumptions

T = KDF
Use N of clamp force and meters of nominal bolt diameter to get N·m. The worksheet can invert the equation to estimate F from torque.
Fproof = Sproof Aₜ
Tensile stress area is π(D − cP)²/4. Use c = 0.938194 for metric and 0.9743 for Unified threads. P is pitch.
dᵈʳⁱˡˡ = D − (% thread)P / 76.98
This is a cut tap geometry estimate. Enter a candidate drill to see the achieved percentage of nominal thread height.

Engineering references

Frequently asked questions

How much does dropping the M12 target from 70% to 60% change torque?

With the same bolt and nut factor, torque scales with target preload. The 60% setting gives about 86% of the torque at 70%.

Is 1.25 mm the ordinary M12 coarse pitch?

Coarse M12 uses 1.75 mm. This example deliberately uses the fine M12 × 1.25 size.