Worked example
Bolt proof load 28,429.09 lbf
- For 10 TPI use a 0.100 in pitch. Subtract 0.9743 times the pitch from 0.750 in, square the result and multiply by π/4.
- Multiply area by 85,000 psi for the proof load. Use the 75% utilization in the worksheet for the target clamp force.
Before using this result. Check actual bolt range, mating nut grade and structural joint requirements. This dry torque assumption describes a single fastener and one assembly condition.
Formulas and assumptions
- T = KDF
- Use N of clamp force and meters of nominal bolt diameter to get N·m. The worksheet can invert the equation to estimate F from torque.
- Fproof = Sproof Aₜ
- Tensile stress area is π(D − cP)²/4. Use c = 0.938194 for metric and 0.9743 for Unified threads. P is pitch.
- dᵈʳⁱˡˡ = D − (% thread)P / 76.98
- This is a cut tap geometry estimate. Enter a candidate drill to see the achieved percentage of nominal thread height.
Engineering references
Frequently asked questions
How does the 3/4 in Grade 5 proof stress change above 1 in?
In the listed SAE J429 range, Grade 5 drops from 85 ksi to 74 ksi above 1 in. The worksheet applies the size band to the grade preset.
How do I calculate a total clamp load for several 3/4 in bolts?
Sum individual estimated clamp loads for an initial estimate. For joint design, evaluate stiffness, tightening sequence and preload scatter.