Worked example

Estimated tightening torque 2.63 lbf·ft

  1. Use Grade 2 proof stress of 55 ksi for this size. Calculate the Unified tensile area from the 0.250 in major diameter and 20 TPI.
  2. Use 60% of proof as the illustrative clamp load. Multiply by 0.250 in and 0.12, then divide lbf·in by 12 for lbf·ft.

Before using this result. Confirm the supplier’s nut factor for the exact anti-seize and verify torque tool range at low wrench settings.

Formulas and assumptions

T = KDF
Use N of clamp force and meters of nominal bolt diameter to get N·m. The worksheet can invert the equation to estimate F from torque.
Fproof = Sproof Aₜ
Tensile stress area is π(D − cP)²/4. Use c = 0.938194 for metric and 0.9743 for Unified threads. P is pitch.
dᵈʳⁱˡˡ = D − (% thread)P / 76.98
This is a cut tap geometry estimate. Enter a candidate drill to see the achieved percentage of nominal thread height.

Engineering references

Frequently asked questions

Can I choose a torque wrench based on the calculated 1/4-20 setting?

Check that the specified setting falls within the tool’s calibrated range. An inch-pound wrench may be better suited to a low setting.

How should I choose K for a specific anti-seize compound?

Use the supplier’s torque–tension data for the compound, bolt finish and application method. Chemistry and coating thickness affect friction.