The 55 ksi Grade 2 preset applies to bolts up to 6 in long and to studs. For longer bolts, enter a verified custom proof stress.
Preliminary estimate. Nut factors are starting assumptions and vary with coatings, lubricant, prevailing torque and reuse. Use the specified joint assembly procedure and the supplier’s actual proof stress. Thread height is a radial geometry measure. Thread stripping and required axial engagement need their own checks.
Worked example
Estimated tightening torque2.63 lbf·ft
Use Grade 2 proof stress of 55 ksi for this size. Calculate the Unified tensile area from the 0.250 in major diameter and 20 TPI.
Use 60% of proof as the illustrative clamp load. Multiply by 0.250 in and 0.12, then divide lbf·in by 12 for lbf·ft.
Before using this result. Confirm the supplier’s nut factor for the exact anti-seize and verify torque tool range at low wrench settings.
Formulas and assumptions
T = KDF
Use N of clamp force and meters of nominal bolt diameter to get N·m. The worksheet can invert the equation to estimate F from torque.
Fproof = Sproof Aₜ
Tensile stress area is π(D − cP)²/4. Use c = 0.938194 for metric and 0.9743 for Unified threads. P is pitch.
dᵈʳⁱˡˡ = D − (% thread)P / 76.98
This is a cut tap geometry estimate. Enter a candidate drill to see the achieved percentage of nominal thread height.