GasCompressLab

API 617 · GPSA §13

Hydrogen purification recycle

A dry hydrogen compressor operates on a 2.0 pressure ratio and a 2,600 kg/h mass flow.

What to check

The low molecular weight elevates specific head. Compare the power to the much smaller mass flow.

Operating readout

Edit inputs ↓
Poly. head
1,024.1kJ/kg
Brake power
967.59kW
Discharge T
124.97°C
Pressure ratio
2×
Within entered thermal envelopeDischarge gas is below the entered casing limit.
Centrifugal stage and pressure–enthalpy pathCENTRIFUGAL STAGEkPa(a)P₁ 650P₂ 130035 °C125 °CPRESSURE / ENTHALPYΔh · kJ/kg130065001310 kJ/kgTHERMAL MARGIN35 K
The solid curve tracks the estimated gas enthalpy rise. The dashed curve shows the isentropic comparison.
Calculated details
Isentropic head
994.58kJ/kg
Equivalent isentropic efficiency
75.75%
Power to gas
948.24kW
Exponent ratio (n − 1) / n
0.36956
Gas temperature rise
89.97K
Casing temperature margin
35.03K
Mass flow used
2,600kg/h

Operating inputs

Compression duty
kPa(a)
kPa(a)
°C
°C
Enter the service limit from the project or vendor.
kg/h
Gas and efficiency
Preset properties are starting values.
kg/kmol
%
%

Calculation basis

Head

Set a = (k − 1)/(kηₚ). Hₚ = ZRT₁[(P₂/P₁)ᵃ − 1]/(MW·a). Compute Hₛ with a = (k − 1)/k.

Temperature and shaft work

T₂ = T₁(P₂/P₁)ᵃ. Gas power is ṁHₚ/ηₚ. Divide by mechanical efficiency to get brake power. Equivalent isentropic efficiency is Hₛηₚ/Hₚ.

Related worked examples