GasCompressLab

API 617 · GPSA §13

Nitrogen utility header make-up

A plant nitrogen compressor raises pressure from 115 to 560 kPa(a) using a normal-volume flow basis.

What to check

A large ratio can push discharge temperature above the casing screen before power is the limiting item.

Operating readout

Edit inputs ↓
Poly. head
189.19kJ/kg
Brake power
180.45kW
Discharge T
257.49°C
Pressure ratio
4.87×
Casing ceiling exceededDischarge gas is above the entered casing temperature limit.
Centrifugal stage and pressure–enthalpy pathCENTRIFUGAL STAGEkPa(a)P₁ 115P₂ 56024 °C257 °CPRESSURE / ENTHALPYΔh · kJ/kg5601150243 kJ/kgTHERMAL MARGIN-72.5 K
The solid curve tracks the estimated gas enthalpy rise. The dashed curve shows the isentropic comparison.
Calculated details
Isentropic head
176.53kJ/kg
Equivalent isentropic efficiency
72.78%
Power to gas
176.84kW
Exponent ratio (n − 1) / n
0.3663
Gas temperature rise
233.49K
Casing temperature margin
-72.49K
Mass flow used
2,624.68kg/h

Operating inputs

Compression duty
kPa(a)
kPa(a)
°C
°C
Enter the service limit from the project or vendor.
Nm³/h
Gas and efficiency
Preset properties are starting values.
kg/kmol
%
%

Calculation basis

Head

Set a = (k − 1)/(kηₚ). Hₚ = ZRT₁[(P₂/P₁)ᵃ − 1]/(MW·a). Compute Hₛ with a = (k − 1)/k.

Temperature and shaft work

T₂ = T₁(P₂/P₁)ᵃ. Gas power is ṁHₚ/ηₚ. Divide by mechanical efficiency to get brake power. Equivalent isentropic efficiency is Hₛηₚ/Hₚ.

Related worked examples