GasCompressLab

API 617 · GPSA §13

Dry plant-air booster

A dry-air service uses 2,900 actual m³/h at suction as the basis for shaft power.

What to check

Switch the flow basis to mass to inspect the density conversion at the suction state.

Operating readout

Edit inputs ↓
Poly. head
56.49kJ/kg
Brake power
81.06kW
Discharge T
101.18°C
Pressure ratio
1.792×
Within entered thermal envelopeDischarge gas is below the entered casing limit.
Centrifugal stage and pressure–enthalpy pathCENTRIFUGAL STAGEkPa(a)P₁ 120P₂ 21530 °C101 °CPRESSURE / ENTHALPYΔh · kJ/kg215120071.5 kJ/kgTHERMAL MARGIN73.8 K
The solid curve tracks the estimated gas enthalpy rise. The dashed curve shows the isentropic comparison.
Calculated details
Isentropic head
55.22kJ/kg
Equivalent isentropic efficiency
77.22%
Power to gas
79.44kW
Exponent ratio (n − 1) / n
0.36166
Gas temperature rise
71.18K
Casing temperature margin
73.82K
Mass flow used
3,999.09kg/h

Operating inputs

Compression duty
kPa(a)
kPa(a)
°C
°C
Enter the service limit from the project or vendor.
m³/h
At the entered suction pressure and temperature.
Gas and efficiency
Preset properties are starting values.
kg/kmol
%
%

Calculation basis

Head

Set a = (k − 1)/(kηₚ). Hₚ = ZRT₁[(P₂/P₁)ᵃ − 1]/(MW·a). Compute Hₛ with a = (k − 1)/k.

Temperature and shaft work

T₂ = T₁(P₂/P₁)ᵃ. Gas power is ṁHₚ/ηₚ. Divide by mechanical efficiency to get brake power. Equivalent isentropic efficiency is Hₛηₚ/Hₚ.