GasCompressLab

Fan similarity · Surge margin

Combustion fan speed increase

A combustion-air fan speeds up with lower air density at the warmer inlet.

What to check

Flow increases linearly with speed, while shaft power reflects the cubic speed law and the new density.

Operating readout

Edit inputs ↓
Scaled flow
37,365.52m³/h
Shaft power
31.86kW
Surge margin
58.66%
Recycle flow
0m³/h
Within modeled surge envelopeProcess demand meets the selected margin at the new speed.
Scaled head–flow curves and surge control lineHEAD / FLOW MAPmN₁ 1450N₂ 1720rpm3150043000 m³/hFLOW / CONTROL LINE218%
Speed-line shapes are illustrative. The marked nominal flow and head follow the entered affinity laws. The demand marker is projected onto the new-speed curve.
Calculated details
Scaled head
225.13m
Equivalent pressure rise
2.24kPa
Dimensionless specific speed
1.80165
Scaled surge point
12,692.41m³/h
Minimum stable flow at target margin
14,102.68m³/h
Demand plus required recycle
30,700m³/h
Turn-down, nominal / minimum
2.65×
Reference shaft power
22.19kW
Speed ratio N₂ / N₁
1.1862×

Operating inputs

Reference point
rpm
m³/h
m
Head is expressed as a length. Use specific energy divided by g.
%
m³/h
kg/m³
New operating point
rpm
×
Enter the ratio as a multiplier.
m³/h
%

Calculation basis

Scale the point

At constant geometry and efficiency, flow scales with speed, head with speed squared, and power with speed cubed times density ratio. Dimensionless specific speed is ω√Q/(gH)^(3/4).

Place the control line

Scale the surge flow linearly with speed. Margin is (process demand − surge flow)/process demand. The target flow is Q_surge/(1 − target margin). Recycle supplies the positive shortfall.

Related worked examples