GasCompressLab

Fan similarity · Surge margin

Recycle during zero-demand startup

A startup case assumes no process demand at a 6,500 rpm operating point.

What to check

The margin ratio is undefined at zero demand. The recycle output still identifies the modeled minimum compressor flow.

Operating readout

Edit inputs ↓
Scaled flow
4,875m³/h
Shaft power
49.31kW
Surge margin
—
Recycle flow
3,693.18m³/h
Demand at or below surgeThe unrecycled demand crosses the scaled surge point.
Scaled head–flow curves and surge control lineHEAD / FLOW MAPmN₁ 9200N₂ 6500rpm2110007930 m³/hFLOW / CONTROL LINE0%
Speed-line shapes are illustrative. The marked nominal flow and head follow the entered affinity laws. The demand marker is projected onto the new-speed curve.
Calculated details
Scaled head
753.75m
Equivalent pressure rise
29.49kPa
Dimensionless specific speed
0.99361
Scaled surge point
3,250m³/h
Minimum stable flow at target margin
3,693.18m³/h
Demand plus required recycle
3,693.18m³/h
Turn-down, nominal / minimum
1.32×
Reference shaft power
147.17kW
Speed ratio N₂ / N₁
0.7065×

Operating inputs

Reference point
rpm
m³/h
m
Head is expressed as a length. Use specific energy divided by g.
%
m³/h
kg/m³
New operating point
rpm
×
Enter the ratio as a multiplier.
m³/h
%

Calculation basis

Scale the point

At constant geometry and efficiency, flow scales with speed, head with speed squared, and power with speed cubed times density ratio. Dimensionless specific speed is ω√Q/(gH)^(3/4).

Place the control line

Scale the surge flow linearly with speed. Margin is (process demand − surge flow)/process demand. The target flow is Q_surge/(1 − target margin). Recycle supplies the positive shortfall.