GasCompressLab

Fan similarity · Surge margin

Variable-speed recycle check

A compressor eases from 11,300 to 9,600 rpm as demand approaches its scaled surge boundary.

What to check

The target flow is surge flow divided by one minus the requested margin. The process demand can remain above surge and still need recycle.

Operating readout

Edit inputs ↓
Scaled flow
10,704.42m³/h
Shaft power
158.62kW
Surge margin
6.13%
Recycle flow
307.23m³/h
Surge margin warningRecycle is required to reach the selected minimum compressor flow.
Scaled head–flow curves and surge control lineHEAD / FLOW MAPmN₁ 11300N₂ 9600rpm21400014500 m³/hFLOW / CONTROL LINE95.9%
Speed-line shapes are illustrative. The marked nominal flow and head follow the entered affinity laws. The demand marker is projected onto the new-speed curve.
Calculated details
Scaled head
1,104.27m
Equivalent pressure rise
43.21kPa
Dimensionless specific speed
1.63298
Scaled surge point
6,711.5m³/h
Minimum stable flow at target margin
7,457.23m³/h
Demand plus required recycle
7,457.23m³/h
Turn-down, nominal / minimum
1.435×
Reference shaft power
272.3kW
Speed ratio N₂ / N₁
0.8496×

Operating inputs

Reference point
rpm
m³/h
m
Head is expressed as a length. Use specific energy divided by g.
%
m³/h
kg/m³
New operating point
rpm
×
Enter the ratio as a multiplier.
m³/h
%

Calculation basis

Scale the point

At constant geometry and efficiency, flow scales with speed, head with speed squared, and power with speed cubed times density ratio. Dimensionless specific speed is ω√Q/(gH)^(3/4).

Place the control line

Scale the surge flow linearly with speed. Margin is (process demand − surge flow)/process demand. The target flow is Q_surge/(1 − target margin). Recycle supplies the positive shortfall.