Fan similarity · Surge margin
Combustion fan speed increase
A combustion-air fan speeds up with lower air density at the warmer inlet.
Flow increases linearly with speed, while shaft power reflects the cubic speed law and the new density.
Operating readout
Edit inputs ↓- Scaled flow
- 37,365.52m³/h
- Shaft power
- 31.86kW
- Surge margin
- 58.66%
- Recycle flow
- 0m³/h
Calculated details
- Scaled head
- 225.13m
- Equivalent pressure rise
- 2.24kPa
- Dimensionless specific speed
- 1.80165
- Scaled surge point
- 12,692.41m³/h
- Minimum stable flow at target margin
- 14,102.68m³/h
- Demand plus required recycle
- 30,700m³/h
- Turn-down, nominal / minimum
- 2.65×
- Reference shaft power
- 22.19kW
- Speed ratio N₂ / N₁
- 1.1862×
Operating inputs
Operating inputs
- Reference speed N₁
- 1,450rpm
- Reference actual flow Q₁
- 31,500m³/h
- Reference head H₁
- 160m
- Reference efficiency
- 73%
- Reference surge flow
- 10,700m³/h
- Reference inlet density
- 1.18kg/m³
- New speed N₂
- 1,720rpm
- Density ratio ρ₂ / ρ₁
- 0.86×
- Actual process demand
- 30,700m³/h
- Target surge margin
- 10%
Calculated details
- Scaled head
- 225.13m
- Equivalent pressure rise
- 2.24kPa
- Dimensionless specific speed
- 1.80165
- Scaled surge point
- 12,692.41m³/h
- Minimum stable flow at target margin
- 14,102.68m³/h
- Demand plus required recycle
- 30,700m³/h
- Turn-down, nominal / minimum
- 2.65×
- Reference shaft power
- 22.19kW
- Speed ratio N₂ / N₁
- 1.1862×
Similarity is a preliminary comparison at homologous operating points. Compressible maps require corrected speed and corrected flow where applicable. Use measured OEM surge and choke points, actual gas properties, valve dynamics, and control design for anti-surge protection.
Calculation basis
Scale the point
At constant geometry and efficiency, flow scales with speed, head with speed squared, and power with speed cubed times density ratio. Dimensionless specific speed is ω√Q/(gH)^(3/4).
Place the control line
Scale the surge flow linearly with speed. Margin is (process demand − surge flow)/process demand. The target flow is Q_surge/(1 − target margin). Recycle supplies the positive shortfall.
Related worked examples
-
Variable-speed recycle check →
A compressor eases from 11,300 to 9,600 rpm as demand approaches its scaled surge boundary.
-
Low-speed operation with no recycle →
A slower speed point maintains demand above the 10% control line at a slightly higher gas density.
-
Recycle during zero-demand startup →
A startup case assumes no process demand at a 6,500 rpm operating point.
-
Narrow compressor turn-down range →
A compressor with a high surge flow is evaluated against a 16% margin target.
-
Process demand below surge →
A sudden reduction in process demand takes the unrecycled operating point below the estimated surge limit.