Hydrogen inverse Joule–Thomson warming

An ambient-temperature hydrogen screen reduces 11,000 kPa(a) to 3,000 kPa(a) with a negative JT coefficient.

What to check

The gas warms on expansion in this preset. Confirm the sign and value at the actual inlet state.

Operating readout

Edit inputs ↓
Outlet temp
32.8°C
JT temp change
4.8K
Hydrate margin
—
Heater duty
0kW
Hydrate curve unavailableHeater duty covers MDMT only. Validate hydration for this composition and pressure.
Choke valve and pressure–temperature pathJT LETDOWN / CHOKEkPa(a)P₁ 11000P₂ 3000ΔT 4.8 KP / T PATHGasMDMT · °C32.8-2911000 kPa(a)3000 kPa(a)PREHEAT REQUIRED0 K
The gas and equilibrium curves share a pressure axis. The dashed MDMT line is based on the entered material limit.
Calculated details
Hydrate equilibrium estimate
—
Gas temperature above MDMT
61.8K
Required upstream temperature lift
0K
Estimated preheated inlet
28°C

Operating inputs

Letdown duty
kPa(a)
kPa(a)
°C
kg/h
°C
K
Gas properties
Properties are illustrative. Use a representative site value.
K/bar
Edit this value to override the preset. Negative values warm upon expansion.
kJ/(kg·K)

Calculation basis

Isenthalpic screening

Use ΔT = −μJT(P₁ − P₂) with a constant user-entered coefficient. A negative coefficient produces warming.

Hydrate and heater screen

Estimate wet natural-gas hydrate temperature from Makogon’s pressure relation with Elgibaly–Elkamel gas-gravity coefficients. Sensible preheater duty is ṁCₚ times the positive deficit to the higher of the hydrate and MDMT screens, including the entered buffer.