GasCompressLab

JT · Makogon · MDMT

Nitrogen purge regulator

A nitrogen-only stream passes a purge regulator with a user-entered JT coefficient of 0.28 K/bar.

What to check

The example illustrates how to override a preset to reflect a particular pressure and temperature window.

Operating readout

Edit inputs ↓
Outlet temp
10°C
JT temp change
-14K
Hydrate margin
—
Heater duty
0kW
Hydrate curve unavailableHeater duty covers MDMT only. Validate hydration for this composition and pressure.
Choke valve and pressure–temperature pathJT LETDOWN / CHOKEkPa(a)P₁ 5900P₂ 900ΔT -14 KP / T PATHGasMDMT · °C24-295900 kPa(a)900 kPa(a)PREHEAT REQUIRED0 K
The gas and equilibrium curves share a pressure axis. The dashed MDMT line is based on the entered material limit.
Calculated details
Hydrate equilibrium estimate
—
Gas temperature above MDMT
39K
Required upstream temperature lift
0K
Estimated preheated inlet
24°C

Operating inputs

Letdown duty
kPa(a)
kPa(a)
°C
kg/h
°C
K
Gas properties
Properties are illustrative. Use a representative site value.
K/bar
Edit this value to override the preset. Negative values warm upon expansion.
kJ/(kg·K)

Calculation basis

Isenthalpic screening

Use ΔT = −μJT(P₁ − P₂) with a constant user-entered coefficient. A negative coefficient produces warming.

Hydrate and heater screen

Estimate wet natural-gas hydrate temperature from Makogon’s pressure relation with Elgibaly–Elkamel gas-gravity coefficients. Sensible preheater duty is ṁCₚ times the positive deficit to the higher of the hydrate and MDMT screens, including the entered buffer.