Non-lubricated nitrogen compressor

Two stages raise a nitrogen-rich supply to 1,250 kPa(a) with a warm intercooler return.

What to check

A warm return sets the starting temperature for stage two and can narrow the cylinder temperature margin.

Operating readout

Edit inputs ↓
Stage ratio
2.118×
Peak temp
140.36°C
Total power
153.69kW
Cylinder VE
92.2%
Cylinder temperature limit exceededA cylinder exceeds the selected service screening temperature.
Cylinder train and stage discharge temperaturesCYLINDERS & INTERCOOLERSkPa(a)CYL 1614CYL 21250DISCHARGE TEMPERATURE°C · r 2.1214029STG 1STG 2CYLINDER DELIVERY92.2% VE
Each cylinder uses the solved common ratio. Intercooler symbols mark where pressure is lost and temperature is reset.
Calculated details
Peak static gas rod load
17.23kN
Rod load utilization
13.79%
Total intercooler duty
53.29kW
Single-stage gas power
160.38kW
Power reduction vs single-stage
4.17%
Service temperature screen
120°C
Temperature margin
-20.36K
Hydrogen vendor shutdown example
—
Mass flow used
3,124.61kg/h

Stage schedule

  1. Stage 1

    Suction
    290kPa(a)
    Discharge
    614.2kPa(a)
    Outlet temp
    111.11°C
    Gas power
    74.03kW
    Cooler duty
    53.29kW
    Gas rod load
    8.42kN
  2. Stage 2

    Suction
    590.2kPa(a)
    Discharge
    1,250kPa(a)
    Outlet temp
    140.36°C
    Gas power
    79.66kW
    Cooler duty
    0kW
    Gas rod load
    17.23kN

Operating inputs

Stage duty
kPa(a)
kPa(a)
°C
°C
kPa
Nm³/h
Gas and cylinder
kg/kmol
%
%
mm
mm
kN

Calculation basis

Solve the pressure ladder

For each cylinder use P_out = rP_in. Subtract the entered pressure loss before the next stage. Solve r until the final discharge matches the target. Without losses r = (P_final/P₁)^(1/N).

Cylinder load and cooling

Clearance-only ηᵥ = 1 − c(r^(1/k) − 1). Use the full bore and rod-side annulus to estimate the maximum static differential gas load. Intercooler duty uses positive sensible heat removal only.