Two-stage wet gathering service

Two cylinders boost separator vapor from 280 to 1,670 kPa(a) with a 17 kPa intercooler loss.

What to check

Read the second-stage suction after the cooler to see why the solved ratio exceeds the ideal equal ratio.

Operating readout

Edit inputs ↓
Stage ratio
2.473×
Peak temp
116.55°C
Total power
146.19kW
Cylinder VE
88.81%
Stages within screening limitsTemperature and static gas rod load are within the entered screening basis.
Cylinder train and stage discharge temperaturesCYLINDERS & INTERCOOLERSkPa(a)CYL 1692CYL 21670DISCHARGE TEMPERATURE°C · r 2.4713532STG 1STG 2CYLINDER DELIVERY88.8% VE
Each cylinder uses the solved common ratio. Intercooler symbols mark where pressure is lost and temperature is reset.
Calculated details
Peak static gas rod load
25.83kN
Rod load utilization
20.67%
Total intercooler duty
67.87kW
Single-stage gas power
158.68kW
Power reduction vs single-stage
7.87%
Service temperature screen
135°C
Temperature margin
18.45K
Hydrogen vendor shutdown example
—
Mass flow used
1,870.49kg/h

Stage schedule

  1. Stage 1

    Suction
    280kPa(a)
    Discharge
    692.37kPa(a)
    Outlet temp
    110.27°C
    Gas power
    72.5kW
    Cooler duty
    67.87kW
    Gas rod load
    10.66kN
  2. Stage 2

    Suction
    675.37kPa(a)
    Discharge
    1,670kPa(a)
    Outlet temp
    116.55°C
    Gas power
    73.69kW
    Cooler duty
    0kW
    Gas rod load
    25.83kN

Operating inputs

Stage duty
kPa(a)
kPa(a)
°C
°C
kPa
Nm³/h
Gas and cylinder
kg/kmol
%
%
mm
mm
kN

Calculation basis

Solve the pressure ladder

For each cylinder use P_out = rP_in. Subtract the entered pressure loss before the next stage. Solve r until the final discharge matches the target. Without losses r = (P_final/P₁)^(1/N).

Cylinder load and cooling

Clearance-only ηᵥ = 1 − c(r^(1/k) − 1). Use the full bore and rod-side annulus to estimate the maximum static differential gas load. Intercooler duty uses positive sensible heat removal only.