GasCompressLab

API 521 · Restriction orifice

Target just above header pressure

An inventory screen approaches 413 kPa(a) with a fixed 410 kPa(a) receiving header.

What to check

The curve slows as the pressure difference closes. An equal or lower target cannot be reached.

Operating readout

Edit inputs ↓
Time to target
3.94min
Peak flow
1,291.56kg/h
Min. gas temp
32°C
15-min RO ID
9.23mm
Within 15-minute benchmarkThe selected pressure target is reached on the entered tank and orifice model.
Vessel blowdown pressure and mass-flow decayVESSEL / RESTRICTION / HEADERmmGas inventoryRO 18DEPRESSURINGP · kPa(a)Flow · kg/h940413129000 min15.6 min15-MINUTE SCREEN3.94 min
Pressure and mass flow use independent scales. The vertical gate marks 15 minutes, and the plotted curves end at the selected pressure target.
Calculated details
Selected absolute target
413kPa(a)
Initial vapor inventory
83.36kg
Choked/subsonic transition pressure
746.31kPa(a)
Transition time if crossed
0.89min
Starting regime
Choked
Target regime
Subsonic
Minimum gas temperature above MDMT
61K

Operating inputs

Vessel and target
m³
bar(a)
°C
kPa(a)
kPa(a)
°C
Restriction and gas
mm
kg/kmol

Calculation basis

Inventory and discharge

Use a uniform vapor inventory with fixed Z and k. Pressure follows mass to the power k for adiabatic operation, or mass directly for isothermal operation. Compute instantaneous gas flux with the choked expression below the critical backpressure ratio and the subsonic nozzle expression above it.

Integrate time

Integrate dM/ṁ down to the selected pressure with a transformed pressure coordinate. Solve the 15-minute orifice diameter using the inverse-area time scaling for this model.

Related worked examples