GasCompressLab

API 521 · Restriction orifice

Separator fire depressuring screen

A 64 m³ vapor inventory depressures adiabatically toward half of initial absolute pressure.

What to check

Compare the entered RO with the modeled 15-minute minimum. Check the fire design target separately.

Operating readout

Edit inputs ↓
Time to target
6min
Peak flow
21,769.88kg/h
Min. gas temp
7.97°C
15-min RO ID
18.335mm
Within 15-minute benchmarkThe selected pressure target is reached on the entered tank and orifice model.
Vessel blowdown pressure and mass-flow decayVESSEL / RESTRICTION / HEADERmmGas inventoryRO 29DEPRESSURINGP · kPa(a)Flow · kg/h560028002180000 min15.6 min15-MINUTE SCREEN6 min
Pressure and mass flow use independent scales. The vertical gate marks 15 minutes, and the plotted curves end at the selected pressure target.
Calculated details
Selected absolute target
2,800kPa(a)
Initial vapor inventory
3,866.9kg
Choked/subsonic transition pressure
338.57kPa(a)
Transition time if crossed
—
Starting regime
Choked
Target regime
Choked
Minimum gas temperature above MDMT
36.97K

Operating inputs

Vessel and target
m³
bar(a)
°C
kPa(a)
°C
Restriction and gas
mm
kg/kmol

Calculation basis

Inventory and discharge

Use a uniform vapor inventory with fixed Z and k. Pressure follows mass to the power k for adiabatic operation, or mass directly for isothermal operation. Compute instantaneous gas flux with the choked expression below the critical backpressure ratio and the subsonic nozzle expression above it.

Integrate time

Integrate dM/ṁ down to the selected pressure with a transformed pressure coordinate. Solve the 15-minute orifice diameter using the inverse-area time scaling for this model.