GasCompressLab

API 521 · Restriction orifice

Small restriction orifice retrofit

An existing 11 mm restriction is compared with a 15-minute depressuring target for a 44 m³ vapor volume.

What to check

Increasing diameter lowers time with inverse-area scaling in this fixed-backpressure model.

Operating readout

Edit inputs ↓
Time to target
32.28min
Peak flow
990.64kg/h
Min. gas temp
2.82°C
15-min RO ID
16.138mm
15-minute time exceededThe modeled restriction does not reach the selected target within the benchmark.
Vessel blowdown pressure and mass-flow decayVESSEL / RESTRICTION / HEADERmmGas inventoryRO 11DEPRESSURINGP · kPa(a)Flow · kg/h2300115099100 min33.6 min15-MINUTE SCREEN32.3 min
Pressure and mass flow use independent scales. The vertical gate marks 15 minutes, and the plotted curves end at the selected pressure target.
Calculated details
Selected absolute target
1,150kPa(a)
Initial vapor inventory
947.5kg
Choked/subsonic transition pressure
254.84kPa(a)
Transition time if crossed
—
Starting regime
Choked
Target regime
Choked
Minimum gas temperature above MDMT
31.82K

Operating inputs

Vessel and target
m³
bar(a)
°C
kPa(a)
°C
Restriction and gas
mm
kg/kmol

Calculation basis

Inventory and discharge

Use a uniform vapor inventory with fixed Z and k. Pressure follows mass to the power k for adiabatic operation, or mass directly for isothermal operation. Compute instantaneous gas flux with the choked expression below the critical backpressure ratio and the subsonic nozzle expression above it.

Integrate time

Integrate dM/ṁ down to the selected pressure with a transformed pressure coordinate. Solve the 15-minute orifice diameter using the inverse-area time scaling for this model.