Worked example
Eccentric rectangular footing by Meyerhof
A column moment shifts the vertical service load toward one edge of a rectangular pad.
Results
Edit inputs ↓- Allowable
- 9.502 ksf
- Ultimate
- 28.506 ksf
- Overburden
- 413.5 psf
- Eff. width
- 5.91 ft
- Bearing wedge
- Groundwater
- Footing base
Applied pressure is within the gross bearing screen.
Calculation details
| Allowable minus applied | 5.012 ksf |
|---|---|
| Wedge effective unit weight γeff | 114.59 pcf |
| Cohesion factor Nc | 42.164 |
| Overburden factor Nq | 29.44 |
| Unit-weight factor Nγ | 31.146 |
| Cohesion contribution | 0 ksf |
| Overburden contribution | 15.28 ksf |
| Soil wedge contribution | 13.226 ksf |
| Width after eccentricity B′ | 5.906 ft |
| Length after eccentricity L′ | 13.123 ft |
| Cohesion / surcharge inclination factor | 1 |
| Wedge inclination factor | 1 |
| Effective plan area | 77.5 ft² |
| Gross allowable load | 736.4 kip |
GeotechSoilLab · Screening sheet · US customary
Eccentric rectangular footing by Meyerhof
| Bearing method | Meyerhof |
|---|---|
| Footing shape | Rectangle |
| Width or diameter B | 8.2021 ft |
| Length L | 13.12336 ft |
| Base depth Df | 3.60892 ft |
| Width eccentricity eₓ | 1.14829 ft |
| Length eccentricity eᵧ | 0 ft |
| Load angle from vertical θ | 0 ° |
| Cohesion c′ | 0 psf |
| Friction angle φ′ | 34 ° |
| Moist weight γ | 114.58585 pcf |
| Saturated weight γsat | 127.31761 pcf |
| Water table depth Dw | 26.24672 ft |
| Bearing safety factor | 3 |
| Applied gross pressure | 4.49037 ksf |
| Allowable | 9.502 ksf |
|---|---|
| Ultimate | 28.506 ksf |
| Overburden | 413.5 psf |
| Eff. width | 5.91 ft |
| Allowable minus applied | 5.012 ksf |
| Wedge effective unit weight γeff | 114.59 pcf |
| Cohesion factor Nc | 42.164 |
| Overburden factor Nq | 29.44 |
| Unit-weight factor Nγ | 31.146 |
| Cohesion contribution | 0 ksf |
| Overburden contribution | 15.28 ksf |
| Soil wedge contribution | 13.226 ksf |
| Width after eccentricity B′ | 5.906 ft |
| Length after eccentricity L′ | 13.123 ft |
| Cohesion / surcharge inclination factor | 1 |
| Wedge inclination factor | 1 |
| Effective plan area | 77.5 ft² |
| Gross allowable load | 736.4 kip |
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Worked result
Reduce the width to 1.8 m and use the resulting effective area and aspect ratio in the bearing check.
- The governing effective dimension is 5.906 ft. Overburden q′ is 413.532 psf and the wedge unit weight is 114.586 pcf.
- Add cohesion, overburden and wedge contributions of 0 ksf, 15.28 ksf and 13.226 ksf to get qᵤ = 28.506 ksf.
- Divide qᵤ by 3 to get a gross allowable pressure of 9.502 ksf.
Allowable9.502 ksfUltimate28.506 ksfOverburden413.5 psfEff. width5.91 ft
Original case inputs
| Bearing method | Meyerhof |
|---|---|
| Footing shape | Rectangle |
| Width or diameter B | 8.2021 ft |
| Length L | 13.12336 ft |
| Base depth Df | 3.60892 ft |
| Width eccentricity eₓ | 1.14829 ft |
| Length eccentricity eᵧ | 0 ft |
| Load angle from vertical θ | 0 ° |
| Cohesion c′ | 0 psf |
| Friction angle φ′ | 34 ° |
| Moist weight γ | 114.58585 pcf |
| Saturated weight γsat | 127.31761 pcf |
| Water table depth Dw | 26.24672 ft |
| Bearing safety factor | 3 |
| Applied gross pressure | 4.49037 ksf |
Method & assumptions
- qᵤ = c′·Nc·sc·dc·ic + q′·Nq·sq·dq·iq + ½ γeff·B′·Nγ·sγ·dγ·iγ. The conservative gross allowable screen is qᵤ / F.S. Compare against vertical service load per effective area.
- Effective overburden q′ sums moist soil above the water table and buoyant soil below it. The wedge term averages moist and buoyant unit weights over the smaller effective dimension below the base.
- Terzaghi uses his general shear Nq and Nc factors and linearly interpolates tabulated Nγ. Strip, square and circular shape factors follow the general shear model. For a rectangle, use the ratio of the smaller to the larger effective dimension.
- Meyerhof uses Nq = exp(π tan φ′) tan²(45° + φ′/2), Nc = (Nq − 1) cot φ′ and Nγ = (Nq − 1) tan(1.4φ′). Depth factors use the original width in Df/B. The circular screen uses a unit plan aspect ratio for vertical load.
- Plan eccentricity reduces B′ = B − 2eₓ and L′ = L − 2eᵧ. Inclined Meyerhof loading uses a centered load, unit shape factors and angle θ from vertical. The wedge factor reaches zero at θ ≥ φ′ for frictional soil. Check sliding, settlement and contact separately.
More worked examples
- Dry strip footing in sandA continuous wall bears on medium-dense sand. The seasonal water table lies below the bearing wedge.
- Square footing with water at gradeA square column pad supports a service load in saturated sand during the high-water season.
- Circular footing with water at its baseA circular equipment pad has a centered vertical load and groundwater at founding level.
- Water table within a footing wedgeThe water table is 1.2 m below the base of a 2.4 m wide rectangular footing.
- Undrained strip footing in clayAn idealized short-term total-stress check treats 42 kPa as undrained cohesion with φ = 0.
- Embedded square footing by MeyerhofAn embedded square pad bears in a dense granular layer below loose surface fill.