Worked example

Embedded square footing by Meyerhof

An embedded square pad bears in a dense granular layer below loose surface fill.

Allowable
521.2 kPa
Ultimate
1,563.5 kPa
Overburden
25.2 kPa
Eff. width
1.8 m
Footing section & failure wedge Schematic
Footing section & failure wedge, schematic GradeB′ 1.8 mWater below wedgeBase at 1.4 mApplied / allowable50.8%
  • Bearing wedge
  • Groundwater
  • Footing base

Applied pressure is within the gross bearing screen.

Calculation details
Allowable minus applied256.2 kPa
Wedge effective unit weight γeff18 kN/m³
Cohesion factor Nc32.671
Overburden factor Nq20.631
Unit-weight factor Nγ18.564
Cohesion contribution338.4 kPa
Overburden contribution776.1 kPa
Soil wedge contribution448.9 kPa
Width after eccentricity B′1.8 m
Length after eccentricity L′1.8 m
Cohesion / surcharge inclination factor1
Wedge inclination factor1
Effective plan area3.24 m²
Gross allowable load1,688.5 kN

Inputs

Footing geometry
For a centered load. Resolve sliding independently.
Soil and groundwater
Depth from grade. Use a deep value for dry conditions.
Vertical service load divided by effective area.

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

An idealized uniform profile exposes how depth and shape corrections change each of the three terms.

  1. The governing effective dimension is 1.8 m. Overburden q′ is 25.2 kPa and the wedge unit weight is 18 kN/m³.
  2. Add cohesion, overburden and wedge contributions of 338.397 kPa, 776.112 kPa and 448.945 kPa to get qᵤ = 1,563.454 kPa.
  3. Divide qᵤ by 3 to get a gross allowable pressure of 521.151 kPa.
Allowable521.2 kPaUltimate1,563.5 kPaOverburden25.2 kPaEff. width1.8 m
Original case inputs
Bearing methodMeyerhof
Footing shapeSquare
Width or diameter B1.8 m
Base depth Df1.4 m
Width eccentricity eₓ0 m
Length eccentricity eᵧ0 m
Load angle from vertical θ0 °
Cohesion c′5 kPa
Friction angle φ′31 °
Moist weight γ18 kN/m³
Saturated weight γsat20 kN/m³
Water table depth Dw6 m
Bearing safety factor3
Applied gross pressure265 kPa

Method & assumptions

  1. qᵤ = c′·Nc·sc·dc·ic + q′·Nq·sq·dq·iq + ½ γeff·B′·Nγ·sγ·dγ·iγ. The conservative gross allowable screen is qᵤ / F.S. Compare against vertical service load per effective area.
  2. Effective overburden q′ sums moist soil above the water table and buoyant soil below it. The wedge term averages moist and buoyant unit weights over the smaller effective dimension below the base.
  3. Terzaghi uses his general shear Nq and Nc factors and linearly interpolates tabulated Nγ. Strip, square and circular shape factors follow the general shear model. For a rectangle, use the ratio of the smaller to the larger effective dimension.
  4. Meyerhof uses Nq = exp(π tan φ′) tan²(45° + φ′/2), Nc = (Nq − 1) cot φ′ and Nγ = (Nq − 1) tan(1.4φ′). Depth factors use the original width in Df/B. The circular screen uses a unit plan aspect ratio for vertical load.
  5. Plan eccentricity reduces B′ = B − 2eₓ and L′ = L − 2eᵧ. Inclined Meyerhof loading uses a centered load, unit shape factors and angle θ from vertical. The wedge factor reaches zero at θ ≥ φ′ for frictional soil. Check sliding, settlement and contact separately.

More worked examples