Worked example

Square footing with water at grade

A square column pad supports a service load in saturated sand during the high-water season.

Allowable
237.9 kPa
Ultimate
713.7 kPa
Overburden
11.9 kPa
Eff. width
2.4 m
Footing section & failure wedge Schematic
Footing section & failure wedge, schematic GradeB′ 2.4 mWater at 0 mBase at 1.1 mApplied / allowable77.8%
  • Bearing wedge
  • Groundwater
  • Footing base

Applied pressure is within the gross bearing screen.

Calculation details
Allowable minus applied52.9 kPa
Wedge effective unit weight γeff10.79 kN/m³
Cohesion factor Nc48.09
Overburden factor Nq32.23
Unit-weight factor Nγ31.95
Cohesion contribution0 kPa
Overburden contribution382.7 kPa
Soil wedge contribution331.1 kPa
Width after eccentricity B′2.4 m
Length after eccentricity L′2.4 m
Cohesion / surcharge inclination factor1
Wedge inclination factor1
Effective plan area5.76 m²
Gross allowable load1,370.3 kN

Inputs

Footing geometry
Soil and groundwater
Depth from grade. Use a deep value for dry conditions.
Vertical service load divided by effective area.

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

Both the overburden and wedge terms use buoyant unit weight.

  1. The governing effective dimension is 2.4 m. Overburden q′ is 11.873 kPa and the wedge unit weight is 10.793 kN/m³.
  2. Add cohesion, overburden and wedge contributions of 0 kPa, 382.655 kPa and 331.054 kPa to get qᵤ = 713.709 kPa.
  3. Divide qᵤ by 3 to get a gross allowable pressure of 237.903 kPa.
Allowable237.9 kPaUltimate713.7 kPaOverburden11.9 kPaEff. width2.4 m
Original case inputs
Bearing methodTerzaghi
Footing shapeSquare
Width or diameter B2.4 m
Base depth Df1.1 m
Width eccentricity eₓ0 m
Length eccentricity eᵧ0 m
Cohesion c′0 kPa
Friction angle φ′33 °
Moist weight γ18.5 kN/m³
Saturated weight γsat20.6 kN/m³
Water table depth Dw0 m
Bearing safety factor3
Applied gross pressure185 kPa

Method & assumptions

  1. qᵤ = c′·Nc·sc·dc·ic + q′·Nq·sq·dq·iq + ½ γeff·B′·Nγ·sγ·dγ·iγ. The conservative gross allowable screen is qᵤ / F.S. Compare against vertical service load per effective area.
  2. Effective overburden q′ sums moist soil above the water table and buoyant soil below it. The wedge term averages moist and buoyant unit weights over the smaller effective dimension below the base.
  3. Terzaghi uses his general shear Nq and Nc factors and linearly interpolates tabulated Nγ. Strip, square and circular shape factors follow the general shear model. For a rectangle, use the ratio of the smaller to the larger effective dimension.
  4. Meyerhof uses Nq = exp(π tan φ′) tan²(45° + φ′/2), Nc = (Nq − 1) cot φ′ and Nγ = (Nq − 1) tan(1.4φ′). Depth factors use the original width in Df/B. The circular screen uses a unit plan aspect ratio for vertical load.
  5. Plan eccentricity reduces B′ = B − 2eₓ and L′ = L − 2eᵧ. Inclined Meyerhof loading uses a centered load, unit shape factors and angle θ from vertical. The wedge factor reaches zero at θ ≥ φ′ for frictional soil. Check sliding, settlement and contact separately.

More worked examples