GlassFacadeLab · ASTM E1300 · Roark plate screening
Rectangular glass plate wind-load calculator
Calculator scenario · SI
Pass · Wind demand and linear bow are within the selected limits.
Inputs
- Width a
- 1.2 m
- Height b
- 2.1 m
- Nominal thickness
- 10 mm
- Minimum thickness t
- 9.5 mm
- Glass treatment
- Heat-strengthened
- Annealed stress reference
- 23.3 MPa
- Wind pressure magnitude
- 1.75 kPa
- Load duration factor
- 1
- Center-bow limit
- L/60, cap 19 mm
Results
- Linear bow
- 6.27 mm
- Center stress
- 15.26 MPa
- Screening LR
- 5.34 kPa
- Load use
- 32.7 %
- Entered aspect b/a
- 1.75
- Restrained-model center bow
- 4.92 mm
- Restrained-model center stress
- 13.607 MPa
- Selected center-bow limit
- 19 mm
- Linear bow utilization
- 33 %
- Glass type factor
- 2
Formula trace in SI
Flexural rigidity
D = E t³ / [12(1 − ν²)]
t = 9.5 mm, D = 5255.732 N·m.
Linear response
w₀ = Cw q aₛ⁴ / D; σ = 6 max(Mx, My) / t²
Cw = 0.009083, aₛ = 1.2 m, w₀ = 6.272 mm.
Restrained response
q = kb w + km w³
q = 1.75 kPa, w = 4.92 mm, σ = 13.607 MPa.
Resistance and demand
LR = σref × GTF × duration / Cσ, with σlinear = Cσ q
GTF 2, LR 5.344 kPa, load use 32.74 %, bow use 33.01 %.