GlassFacadeLab · ASTM E1300 · Roark plate screening
Square museum infill lite
Worked example · SI
Warn · Linear center bow exceeds one glass thickness. Review large-deflection behavior.
Inputs
- Width a
- 1.45 m
- Height b
- 1.45 m
- Nominal thickness
- 8 mm
- Minimum thickness t
- 7.5 mm
- Glass treatment
- Heat-strengthened
- Annealed stress reference
- 23.3 MPa
- Wind pressure magnitude
- 1.45 kPa
- Load duration factor
- 1
- Center-bow limit
- L/60, cap 19 mm
Results
- Linear bow
- 10.07 mm
- Center stress
- 14.61 MPa
- Screening LR
- 4.62 kPa
- Load use
- 31.4 %
- Entered aspect b/a
- 1
- Restrained-model center bow
- 6.229 mm
- Restrained-model center stress
- 11.085 MPa
- Selected center-bow limit
- 19 mm
- Linear bow utilization
- 53 %
- Glass type factor
- 2
Formula trace in SI
Flexural rigidity
D = E t³ / [12(1 − ν²)]
t = 7.5 mm, D = 2586.105 N·m.
Linear response
w₀ = Cw q aₛ⁴ / D; σ = 6 max(Mx, My) / t²
Cw = 0.004062, aₛ = 1.45 m, w₀ = 10.069 mm.
Restrained response
q = kb w + km w³
q = 1.45 kPa, w = 6.229 mm, σ = 11.085 MPa.
Resistance and demand
LR = σref × GTF × duration / Cσ, with σlinear = Cσ q
GTF 2, LR 4.624 kPa, load use 31.36 %, bow use 52.99 %.