Windward hotel window band

A repetitive narrow facade bay has a modest pressure and a short-edge bow limit.

ASTM E1300 · Roark plate screening

Inputs

Glass lite
m
m
mm
mm

Use the minimum thickness certified for the lite.

MPa

Editable screening assumption.

Load and limit
kPa

Factor on reference resistance. Use 1 for the default short-load screen.

Screening result

Linear center bow exceeds one glass thickness. Review large-deflection behavior.

Warn
Linear bow
8.47mm
Center stress
25.69MPa
Screening LR
3.27kPa
Load use
55.1%
Glass-lite elevation and load–deflection curveGlass plate wind load. Linear bow 8.47 mm. Center stress 25.69 MPa. Screening LR 3.27 kPa. Load use 55.1 %.Four-edge-supported liteHeight 2.2 m · pressure 1.8 kPaa = 0.82 mPressure vs. center bowPressure (kPa)2.10010.33 mmLinearRestrainedGoverning demand0%100% limit200%+

Calculation details

Entered aspect b/a
2.683
Restrained-model center bow
4.728 mm
Restrained-model center stress
17.443 MPa
Selected center-bow limit
13.667 mm
Linear bow utilization
62 %
Glass type factor
2

Formula trace in SI

  1. Flexural rigidity

    D = E t³ / [12(1 − ν²)]

    t = 5.7 mm, D = 1135.238 N·m.

  2. Linear response

    w₀ = Cw q aₛ⁴ / D; σ = 6 max(Mx, My) / t²

    Cw = 0.011821, aₛ = 0.82 m, w₀ = 8.474 mm.

  3. Restrained response

    q = kb w + km w³

    q = 1.8 kPa, w = 4.728 mm, σ = 17.443 MPa.

  4. Resistance and demand

    LR = σref × GTF × duration / Cσ, with σlinear = Cσ q

    GTF 2, LR 3.266 kPa, load use 55.12 %, bow use 62 %.