GlassFacadeLab · ASTM E1300 · Roark plate screening
Windward hotel window band
Worked example · SI
Warn · Linear center bow exceeds one glass thickness. Review large-deflection behavior.
Inputs
- Width a
- 0.82 m
- Height b
- 2.2 m
- Nominal thickness
- 6 mm
- Minimum thickness t
- 5.7 mm
- Glass treatment
- Heat-strengthened
- Annealed stress reference
- 23.3 MPa
- Wind pressure magnitude
- 1.8 kPa
- Load duration factor
- 1
- Center-bow limit
- L/60 of short edge
Results
- Linear bow
- 8.47 mm
- Center stress
- 25.69 MPa
- Screening LR
- 3.27 kPa
- Load use
- 55.1 %
- Entered aspect b/a
- 2.683
- Restrained-model center bow
- 4.728 mm
- Restrained-model center stress
- 17.443 MPa
- Selected center-bow limit
- 13.667 mm
- Linear bow utilization
- 62 %
- Glass type factor
- 2
Formula trace in SI
Flexural rigidity
D = E t³ / [12(1 − ν²)]
t = 5.7 mm, D = 1135.238 N·m.
Linear response
w₀ = Cw q aₛ⁴ / D; σ = 6 max(Mx, My) / t²
Cw = 0.011821, aₛ = 0.82 m, w₀ = 8.474 mm.
Restrained response
q = kb w + km w³
q = 1.8 kPa, w = 4.728 mm, σ = 17.443 MPa.
Resistance and demand
LR = σref × GTF × duration / Cσ, with σlinear = Cσ q
GTF 2, LR 3.266 kPa, load use 55.12 %, bow use 62 %.