Wide lobby glazing module

The architect has set a 19 mm center-bow limit for a wide entry module.

ASTM E1300 · Roark plate screening

Inputs

Glass lite
m
m
mm
mm

Use the minimum thickness certified for the lite.

MPa

Editable screening assumption.

Load and limit
kPa

Factor on reference resistance. Use 1 for the default short-load screen.

Screening result

Wind demand and linear bow are within the selected limits.

Pass
Linear bow
5.84mm
Center stress
8.78MPa
Screening LR
8.22kPa
Load use
18.9%
Glass-lite elevation and load–deflection curveGlass plate wind load. Linear bow 5.84 mm. Center stress 8.78 MPa. Screening LR 8.22 kPa. Load use 18.9 %.Four-edge-supported liteHeight 2.8 m · pressure 1.55 kPaa = 2.15 mPressure vs. center bowPressure (kPa)1.8007.12 mmLinearRestrainedGoverning demand0%100% limit200%+

Calculation details

Entered aspect b/a
1.302
Restrained-model center bow
5.395 mm
Restrained-model center stress
8.761 MPa
Selected center-bow limit
19 mm
Linear bow utilization
30.7 %
Glass type factor
2

Formula trace in SI

  1. Flexural rigidity

    D = E t³ / [12(1 − ν²)]

    t = 18.1 mm, D = 36349.47 N·m.

  2. Linear response

    w₀ = Cw q aₛ⁴ / D; σ = 6 max(Mx, My) / t²

    Cw = 0.006409, aₛ = 2.15 m, w₀ = 5.839 mm.

  3. Restrained response

    q = kb w + km w³

    q = 1.55 kPa, w = 5.395 mm, σ = 8.761 MPa.

  4. Resistance and demand

    LR = σref × GTF × duration / Cσ, with σlinear = Cσ q

    GTF 2, LR 8.223 kPa, load use 18.85 %, bow use 30.73 %.