GlassFacadeLab · ASTM E1300 · Roark plate screening
Tall atrium tempered lite
Worked example · SI
Pass · Wind demand and linear bow are within the selected limits.
Inputs
- Width a
- 1.1 m
- Height b
- 4.2 m
- Nominal thickness
- 12 mm
- Minimum thickness t
- 11.5 mm
- Glass treatment
- Fully tempered
- Annealed stress reference
- 23.3 MPa
- Wind pressure magnitude
- 2.4 kPa
- Load duration factor
- 1
- Center-bow limit
- L/60 of short edge
Results
- Linear bow
- 4.81 mm
- Center stress
- 16.19 MPa
- Screening LR
- 13.82 kPa
- Load use
- 17.4 %
- Entered aspect b/a
- 3.818
- Restrained-model center bow
- 4.161 mm
- Restrained-model center stress
- 15.323 MPa
- Selected center-bow limit
- 18.333 mm
- Linear bow utilization
- 26.2 %
- Glass type factor
- 4
Formula trace in SI
Flexural rigidity
D = E t³ / [12(1 − ν²)]
t = 11.5 mm, D = 9323.004 N·m.
Linear response
w₀ = Cw q aₛ⁴ / D; σ = 6 max(Mx, My) / t²
Cw = 0.012761, aₛ = 1.1 m, w₀ = 4.81 mm.
Restrained response
q = kb w + km w³
q = 2.4 kPa, w = 4.161 mm, σ = 15.323 MPa.
Resistance and demand
LR = σref × GTF × duration / Cσ, with σlinear = Cσ q
GTF 4, LR 13.819 kPa, load use 17.37 %, bow use 26.23 %.