Tall atrium tempered lite

A narrow lite sits between close vertical mullions at a tall atrium.

ASTM E1300 · Roark plate screening

Inputs

Glass lite
m
m
mm
mm

Use the minimum thickness certified for the lite.

MPa

Editable screening assumption.

Load and limit
kPa

Factor on reference resistance. Use 1 for the default short-load screen.

Screening result

Wind demand and linear bow are within the selected limits.

Pass
Linear bow
4.81mm
Center stress
16.19MPa
Screening LR
13.82kPa
Load use
17.4%
Glass-lite elevation and load–deflection curveGlass plate wind load. Linear bow 4.81 mm. Center stress 16.19 MPa. Screening LR 13.82 kPa. Load use 17.4 %.Four-edge-supported liteHeight 4.2 m · pressure 2.4 kPaa = 1.1 mPressure vs. center bowPressure (kPa)2.8005.86 mmLinearRestrainedGoverning demand0%100% limit200%+

Calculation details

Entered aspect b/a
3.818
Restrained-model center bow
4.161 mm
Restrained-model center stress
15.323 MPa
Selected center-bow limit
18.333 mm
Linear bow utilization
26.2 %
Glass type factor
4

Formula trace in SI

  1. Flexural rigidity

    D = E t³ / [12(1 − ν²)]

    t = 11.5 mm, D = 9323.004 N·m.

  2. Linear response

    w₀ = Cw q aₛ⁴ / D; σ = 6 max(Mx, My) / t²

    Cw = 0.012761, aₛ = 1.1 m, w₀ = 4.81 mm.

  3. Restrained response

    q = kb w + km w³

    q = 2.4 kPa, w = 4.161 mm, σ = 15.323 MPa.

  4. Resistance and demand

    LR = σref × GTF × duration / Cσ, with σlinear = Cσ q

    GTF 4, LR 13.819 kPa, load use 17.37 %, bow use 26.23 %.