Canopy lite duration sensitivity

An equivalent sustained normal pressure is entered for a four-edge-supported canopy lite.

ASTM E1300 · Roark plate screening

Inputs

Glass lite
m
m
mm
mm

Use the minimum thickness certified for the lite.

MPa

Editable screening assumption.

Load and limit
kPa

Factor on reference resistance. Use 1 for the default short-load screen.

Screening result

Wind demand and linear bow are within the selected limits.

Pass
Linear bow
3.74mm
Center stress
8.33MPa
Screening LR
9.06kPa
Load use
14.9%
Glass-lite elevation and load–deflection curveGlass plate wind load. Linear bow 3.74 mm. Center stress 8.33 MPa. Screening LR 9.06 kPa. Load use 14.9 %.Four-edge-supported liteHeight 1.85 m · pressure 1.35 kPaa = 1.4 mPressure vs. center bowPressure (kPa)1.6004.56 mmLinearRestrainedGoverning demand0%100% limit200%+

Calculation details

Entered aspect b/a
1.321
Restrained-model center bow
3.444 mm
Restrained-model center stress
8.296 MPa
Selected center-bow limit
19 mm
Linear bow utilization
19.7 %
Glass type factor
4

Formula trace in SI

  1. Flexural rigidity

    D = E t³ / [12(1 − ν²)]

    t = 11.4 mm, D = 9081.904 N·m.

  2. Linear response

    w₀ = Cw q aₛ⁴ / D; σ = 6 max(Mx, My) / t²

    Cw = 0.006545, aₛ = 1.4 m, w₀ = 3.737 mm.

  3. Restrained response

    q = kb w + km w³

    q = 1.35 kPa, w = 3.444 mm, σ = 8.296 MPa.

  4. Resistance and demand

    LR = σref × GTF × duration / Cσ, with σlinear = Cσ q

    GTF 4, LR 9.062 kPa, load use 14.9 %, bow use 19.67 %.