Atrium mullion with long-span cap

A tall glazing edge uses a project-specified 19 mm limit at long spans.

L/175 · L/240 · 19 mm cap

Inputs

Span and loading
m
m
kPa
Aluminum section
cm⁴
cm³
GPa
MPa

0 uses the illustrative alloy allowance.

Screening result

Mullion deflection or bending stress exceeds the selected limit.

Fail
Deflection
25.16mm
Service limit
19mm
Bend stress
69.3MPa
Bending use
63%
Curtain-wall tributary loading and beam responseCurtain-wall mullion. Deflection 25.16 mm. Service limit 19 mm. Bend stress 69.3 MPa. Bending use 63 %.Wind load onto mullionTrapezoidal · span 4.25 mPeak 2.64 kN/mOut-of-plane responseSimply supported spanMδMomentDeflectionGoverning mullion demand0%100% limit200%+

Calculation details

Peak tributary line load
2.64 kN/m
Maximum absolute bending moment
5.679 kN·m
Uncapped L/175
24.286 mm
L/175 with long-span cap
19 mm
L/240 reference
17.708 mm
Elastic modulus
69 GPa
Selected bending allowance
110 MPa
Deflection utilization
132.4 %

Formula trace in SI

  1. Tributary wind

    w(x) = q min(B, 2x, 2(L − x))

    Trapezoidal load, peak 2.64 kN/m.

  2. Beam response

    EI y″ = M(x); σ = |M|max / Sx

    Zero displacement at both pins. |M|max = 5.679 kN·m, δmax = 25.156 mm.

  3. Service criterion

    δallow = L/175, capped at 19 mm if L > 4.1 m

    Selected 19 mm, deflection use 132.4 %.

  4. Bending criterion

    Utilization = σ / σallow

    69.256 MPa / 110 MPa = 62.96 %.