Storefront simple-span mullion

A shallow extrusion spans between sill and head in a street-level glazed bay.

L/175 · L/240 · 19 mm cap

Inputs

Span and loading
m
m
kPa
Aluminum section
cm⁴
cm³
GPa
MPa

0 uses the illustrative alloy allowance.

Screening result

The modeled mullion is within both selected limits.

Pass
Deflection
11.64mm
Service limit
16.29mm
Bend stress
51.6MPa
Bending use
46.9%
Curtain-wall tributary loading and beam responseCurtain-wall mullion. Deflection 11.64 mm. Service limit 16.29 mm. Bend stress 51.6 MPa. Bending use 46.9 %.Wind load onto mullionTrapezoidal · span 2.85 mPeak 1.47 kN/mOut-of-plane responseSimply supported spanMδMomentDeflectionGoverning mullion demand0%100% limit200%+

Calculation details

Peak tributary line load
1.472 kN/m
Maximum absolute bending moment
1.394 kN·m
Uncapped L/175
16.286 mm
L/175 with long-span cap
16.286 mm
L/240 reference
11.875 mm
Elastic modulus
69 GPa
Selected bending allowance
110 MPa
Deflection utilization
71.5 %

Formula trace in SI

  1. Tributary wind

    w(x) = q min(B, 2x, 2(L − x))

    Trapezoidal load, peak 1.472 kN/m.

  2. Beam response

    EI y″ = M(x); σ = |M|max / Sx

    Zero displacement at both pins. |M|max = 1.394 kN·m, δmax = 11.64 mm.

  3. Service criterion

    δallow = L/175, capped at 19 mm if L > 4.1 m

    Selected 16.286 mm, deflection use 71.47 %.

  4. Bending criterion

    Utilization = σ / σallow

    51.632 MPa / 110 MPa = 46.94 %.