Wide bay with triangular loading

The tributary bay is wider than the supported mullion span.

L/175 · L/240 · 19 mm cap

Inputs

Span and loading
m
m
kPa
Aluminum section
cm⁴
cm³
GPa
MPa

0 uses the illustrative alloy allowance.

Screening result

The modeled mullion is within both selected limits.

Pass
Deflection
5.87mm
Service limit
14.29mm
Bend stress
46.5MPa
Bending use
28.2%
Curtain-wall tributary loading and beam responseCurtain-wall mullion. Deflection 5.87 mm. Service limit 14.29 mm. Bend stress 46.5 MPa. Bending use 28.2 %.Wind load onto mullionTriangular · span 2.5 mPeak 3.3 kN/mOut-of-plane responseSimply supported spanMδMomentDeflectionGoverning mullion demand0%100% limit200%+

Calculation details

Peak tributary line load
3.3 kN/m
Maximum absolute bending moment
1.719 kN·m
Uncapped L/175
14.286 mm
L/175 with long-span cap
14.286 mm
L/240 reference
10.417 mm
Elastic modulus
69 GPa
Selected bending allowance
165 MPa
Deflection utilization
41.1 %

Formula trace in SI

  1. Tributary wind

    w(x) = q min(B, 2x, 2(L − x))

    Triangular load, peak 3.3 kN/m.

  2. Beam response

    EI y″ = M(x); σ = |M|max / Sx

    Zero displacement at both pins. |M|max = 1.719 kN·m, δmax = 5.875 mm.

  3. Service criterion

    δallow = L/175, capped at 19 mm if L > 4.1 m

    Selected 14.286 mm, deflection use 41.12 %.

  4. Bending criterion

    Utilization = σ / σallow

    46.453 MPa / 165 MPa = 28.15 %.