GlassFacadeLab · Solar absorption · Edge restraint
Clear glass with narrow frame shade
Worked example · SI
Pass · Modeled edge tension is within the entered allowance.
Inputs
- Solar absorptance
- 0.17
- Peak solar irradiance
- 570 W/m²
- Indoor reference temperature
- 22 °C
- Shaded edge temperature
- 20 °C
- Frame shadow band
- 17 mm
- Effective heat transfer
- 15 W/(m²·K)
- Edge finish
- Ground
- Glass treatment
- Annealed
- Clean-cut annealed allowance
- 18 MPa
Results
- Center–edge ΔT
- 8.5 K
- Edge stress
- 3.59 MPa
- Edge allowance
- 18.9 MPa
- Safety factor
- 5.268
- Sunlit center temperature
- 28.46 °C
- Shaded edge temperature
- 20 °C
- Absorbed solar flux
- 96.9 W/m²
- Frame restraint assumption
- 0.673
- Edge stress utilization
- 19 %
Formula trace in SI
Absorbed heat
qsolar = α I; Tcenter = Tindoor + qsolar/heff
Absorbed 96.9 W/m², center 28.46 °C.
Edge tension
σth = E αglass max(ΔT, 0) Kframe
ΔT 8.46 K, Kframe 0.673, stress 3.588 MPa.
Edge allowance
σallow = σref × edge factor × treatment factor
Factors 1.05 × 1, allowance 18.9 MPa.