GlassFacadeLab · L/175 · L/240 · 19 mm cap
Storefront simple-span mullion
Worked example · SI
Pass · The modeled mullion is within both selected limits.
Inputs
- Span L per bay
- 2.85 m
- Tributary spacing B
- 1.28 m
- Wind pressure magnitude
- 1.15 kPa
- Support condition
- Simply supported
- Service limit
- L/175 with long-span cap
- Second moment Iₓ
- 145 cm⁴
- Section modulus Sₓ
- 27 cm³
- Extrusion alloy
- 6063-T6
- Elastic modulus E
- 69 GPa
- Bending allowance override
- 0 MPa
Results
- Deflection
- 11.64 mm
- Service limit
- 16.29 mm
- Bend stress
- 51.6 MPa
- Bending use
- 46.9 %
- Peak tributary line load
- 1.472 kN/m
- Maximum absolute bending moment
- 1.394 kN·m
- Uncapped L/175
- 16.286 mm
- L/175 with long-span cap
- 16.286 mm
- L/240 reference
- 11.875 mm
- Elastic modulus
- 69 GPa
- Selected bending allowance
- 110 MPa
- Deflection utilization
- 71.5 %
Formula trace in SI
Tributary wind
w(x) = q min(B, 2x, 2(L − x))
Trapezoidal load, peak 1.472 kN/m.
Beam response
EI y″ = M(x); σ = |M|max / Sx
Zero displacement at both pins. |M|max = 1.394 kN·m, δmax = 11.64 mm.
Service criterion
δallow = L/175, capped at 19 mm if L > 4.1 m
Selected 16.286 mm, deflection use 71.47 %.
Bending criterion
Utilization = σ / σallow
51.632 MPa / 110 MPa = 46.94 %.