GlassFacadeLab · L/175 · L/240 · 19 mm cap
Wide bay with triangular loading
Worked example · SI
Pass · The modeled mullion is within both selected limits.
Inputs
- Span L per bay
- 2.5 m
- Tributary spacing B
- 2.85 m
- Wind pressure magnitude
- 1.32 kPa
- Support condition
- Simply supported
- Service limit
- L/175 with long-span cap
- Second moment Iₓ
- 265 cm⁴
- Section modulus Sₓ
- 37 cm³
- Extrusion alloy
- 6061-T6
- Elastic modulus E
- 69 GPa
- Bending allowance override
- 0 MPa
Results
- Deflection
- 5.87 mm
- Service limit
- 14.29 mm
- Bend stress
- 46.5 MPa
- Bending use
- 28.2 %
- Peak tributary line load
- 3.3 kN/m
- Maximum absolute bending moment
- 1.719 kN·m
- Uncapped L/175
- 14.286 mm
- L/175 with long-span cap
- 14.286 mm
- L/240 reference
- 10.417 mm
- Elastic modulus
- 69 GPa
- Selected bending allowance
- 165 MPa
- Deflection utilization
- 41.1 %
Formula trace in SI
Tributary wind
w(x) = q min(B, 2x, 2(L − x))
Triangular load, peak 3.3 kN/m.
Beam response
EI y″ = M(x); σ = |M|max / Sx
Zero displacement at both pins. |M|max = 1.719 kN·m, δmax = 5.875 mm.
Service criterion
δallow = L/175, capped at 19 mm if L > 4.1 m
Selected 14.286 mm, deflection use 41.12 %.
Bending criterion
Utilization = σ / σallow
46.453 MPa / 165 MPa = 28.15 %.